15 | Operation
Installer and user reference guide
63
FCAG35~140BVEB
Split system air conditioners
4P561448-1B – 2021.07
In combination with R32 outdoor units
Outdoor units Cooling Heating
RXM35~60 –10~46°CDB –15~24°CDB
–15~18°CWB
14~28°CDB 10~30°CDB
3MXM40~68
4MXM68~80
5MXM90
–10~46°CDB –15~24°CDB
–15~18°CWB
18~37°CDB
14~28°C WB
10~30°CDB
RZAG35~60 –20~52°CDB –20~24°CDB
–21~18°CWB
17~38°CDB
12~28°CWB
10~27°CDB
RZAG71~140 –20~52°CDB –20~24°CDB
–20~18°CWB
17~38°CDB
12~28°CWB
10~27°CDB
RZASG71~140 –15~46°CDB –15~21°CDB
–15~15.5°CWB
20~38°CDB
14~28°CWB
10~27°CDB
AZAS71~140 –5~46°CDB –15~21°CDB
–15~15.5°CWB
20~38°CDB
14~28°CWB
10~27°CDB
Indoor humidity ≤80%
(a)
(a)
To avoid condensation and water dripping out of the unit. If the temperature or the
humidity is beyond these conditions, safety devices may be put in action and the air
conditioner may not operate.
Outdoor temperature
Indoor temperature
15.2 Operating the system
15.2.1 About operating the system
To protect the unit, turn on the main power switch 6 hours before operation.
If the main power supply is turned off during operation, operation will restart
automatically after the power turns back on again.