INSTALLATION MANUAL
OPERATION MANUAL
CEILING CONCEALED SPLIT TYPE
AIR-CONDITIONER
FDKR200AV16
FDKR300AV16
FDKR400AV16
3P724053-2
Question and Answer IconNeed help?

Do you have a question about the Daikin FDKR200AV16 and is the answer not in the manual?

Summary

Installation Manual

Installation Safety Precautions

Critical warnings and cautions for safe installation and operation of the air conditioner.

Indoor Unit Installation and Drain Piping

Procedures for mounting the indoor unit, clearances, and drain piping work.

Outdoor Unit Installation Location

Guidelines for selecting the best location for the outdoor unit for optimal performance.

Outdoor Unit Installation Clearance

Spacing guidelines for outdoor units to prevent hot air recirculation and ensure service access.

Indoor Unit Outline and Dimensions

Physical dimensions and specifications for FDKR200AV16 and FDKR300AV16 indoor units.

FDKR400 AV16 Indoor Unit Dimensions

Physical dimensions and specifications for the FDKR400AV16 indoor unit.

Outdoor Unit Dimensions and Air Discharge

Dimensions and airflow clearance for outdoor units RZR200AY16, RZR300AY16, RZR400AY16.

Refrigerant Piping and Bends

Guidelines for maximum pipe length, number of bends, and pipe size details.

Piping Work and Brazing Techniques

Instructions for piping connection, brazing, and torque specifications.

Electrical Wiring Work and Specifications

Wiring requirements, cable sizes, conductor counts, and overall checking procedures.

Outdoor Unit Field Wiring Instructions

Wiring diagrams for 5.5Tr and 8.5Tr outdoor units.

11 Tr Outdoor Unit Field Wiring

Wiring diagram for the 11Tr outdoor unit.

Oil Refill Charge Guidelines

Procedures and table for refilling compressor oil based on pipe length.

Vacuuming and Refrigerant Charging

Steps for vacuuming the system and charging the refrigerant, including precautions.

Special Precautions for Scroll Compressors

Specific charging procedures and warnings for units with scroll compressors.

Standard Operating Conditions

Graph showing cooling operation limits based on outdoor and indoor temperatures.

Service and Maintenance Procedures

Maintenance tasks for indoor air filters and unit panels.

Operation Manual

Operation Safety Precautions

General safety warnings and cautions for operating the air conditioner.

Installation Site Recommendations

Guidelines for selecting suitable installation locations, avoiding specific environments.

Operation Procedure and Power Management

Steps for starting operation and power management for seasonal use.

Cooling Operation Characteristics

Explanation of frost formation and automatic defrost operation during cooling.

Operating Range Limits

Temperature and humidity ranges for indoor and outdoor units.

Optimum Operation Guidelines

Tips for efficient operation, including window management and energy saving.

Operating Instructions - Controls and Display

Explanation of the remote controller display, temperature, mode, and fan speed settings.

Operating Instructions - Menu and Timer

Details on menu options, keypad lock, clock setting, timer functions, and energy saver.

Malfunction Codes and Descriptions

List of error codes and their corresponding descriptions and measures.

Troubleshooting Common Issues

Common faults, their causes, and recommended actions for troubleshooting.

Troubleshooting Specific Faults

Detailed troubleshooting for specific error displays like C9, C4, E3, E4, U4, A5.

Summary

Installation Manual

Installation Safety Precautions

Critical warnings and cautions for safe installation and operation of the air conditioner.

Indoor Unit Installation and Drain Piping

Procedures for mounting the indoor unit, clearances, and drain piping work.

Outdoor Unit Installation Location

Guidelines for selecting the best location for the outdoor unit for optimal performance.

Outdoor Unit Installation Clearance

Spacing guidelines for outdoor units to prevent hot air recirculation and ensure service access.

Indoor Unit Outline and Dimensions

Physical dimensions and specifications for FDKR200AV16 and FDKR300AV16 indoor units.

FDKR400 AV16 Indoor Unit Dimensions

Physical dimensions and specifications for the FDKR400AV16 indoor unit.

Outdoor Unit Dimensions and Air Discharge

Dimensions and airflow clearance for outdoor units RZR200AY16, RZR300AY16, RZR400AY16.

Refrigerant Piping and Bends

Guidelines for maximum pipe length, number of bends, and pipe size details.

Piping Work and Brazing Techniques

Instructions for piping connection, brazing, and torque specifications.

Electrical Wiring Work and Specifications

Wiring requirements, cable sizes, conductor counts, and overall checking procedures.

Outdoor Unit Field Wiring Instructions

Wiring diagrams for 5.5Tr and 8.5Tr outdoor units.

11 Tr Outdoor Unit Field Wiring

Wiring diagram for the 11Tr outdoor unit.

Oil Refill Charge Guidelines

Procedures and table for refilling compressor oil based on pipe length.

Vacuuming and Refrigerant Charging

Steps for vacuuming the system and charging the refrigerant, including precautions.

Special Precautions for Scroll Compressors

Specific charging procedures and warnings for units with scroll compressors.

Standard Operating Conditions

Graph showing cooling operation limits based on outdoor and indoor temperatures.

Service and Maintenance Procedures

Maintenance tasks for indoor air filters and unit panels.

Operation Manual

Operation Safety Precautions

General safety warnings and cautions for operating the air conditioner.

Installation Site Recommendations

Guidelines for selecting suitable installation locations, avoiding specific environments.

Operation Procedure and Power Management

Steps for starting operation and power management for seasonal use.

Cooling Operation Characteristics

Explanation of frost formation and automatic defrost operation during cooling.

Operating Range Limits

Temperature and humidity ranges for indoor and outdoor units.

Optimum Operation Guidelines

Tips for efficient operation, including window management and energy saving.

Operating Instructions - Controls and Display

Explanation of the remote controller display, temperature, mode, and fan speed settings.

Operating Instructions - Menu and Timer

Details on menu options, keypad lock, clock setting, timer functions, and energy saver.

Malfunction Codes and Descriptions

List of error codes and their corresponding descriptions and measures.

Troubleshooting Common Issues

Common faults, their causes, and recommended actions for troubleshooting.

Troubleshooting Specific Faults

Detailed troubleshooting for specific error displays like C9, C4, E3, E4, U4, A5.

Overview

This document provides installation and operation manuals for Daikin Ceiling Concealed Split Type Air Conditioners, specifically models FDKR200AV16, FDKR300AV16, and FDKR400AV16.

Function Description:

The Daikin Ceiling Concealed Split Type Air Conditioner is designed to provide cooling for various environments, including shops, light industry, farms, and commercial use. It operates as a split system, meaning it consists of an indoor unit (fan-coil) and an outdoor unit (condensing unit) connected by refrigerant piping. The system uses R410A refrigerant, which is a mixed refrigerant that does not contain chlorine, does not destroy the ozone layer, and contributes only slightly to the greenhouse effect if released. The unit is designed for concealed installation within the ceiling, offering a discreet aesthetic while providing efficient air conditioning.

Important Technical Specifications:

  • Models Covered: FDKR200AV16, FDKR300AV16, FDKR400AV16 (Indoor Units) and RZR200AY16, RZR300AY16, RZR400AY16 (Outdoor Units).
  • Refrigerant: R410A.
  • Design Pressure: 4.17 MPa.
  • Refrigerant Charging: Must be charged in its liquid state to prevent composition change.
  • Power Supply (Voltage Range):
    • Indoor Unit: 230V/1Ph/50Hz/
    • Outdoor Unit: 415V/3Ph/50Hz/
  • Power Supply Cable Size (mm²):
    • FDKR200AV16/RZR200AY16: 2.5
    • FDKR300AV16/RZR300AY16: 4.0
    • FDKR400AV16/RZR400AY16: 6.0
  • Number of Conductors (Power Supply): 5.0 for all models.
  • Interconnection Cable Size (mm²):
    • FDKR200AV16/RZR200AY16: 1.0
    • FDKR300AV16/RZR300AY16: 1.0
    • FDKR400AV16/RZR400AY16: 1.5
  • Number of Conductors (Interconnection): 7.0 for all models.
  • Recommended Fuse (A):
    • FDKR200AV16/RZR200AY16: 20
    • FDKR300AV16/RZR300AY16: 32
    • FDKR400AV16/RZR400AY16: 40
  • Maximum Pipe Length: 40 m (131.2 ft) for all models.
  • Maximum Elevation: 20 m (65.6 ft) for all models.
  • Maximum Number of Bends: 8 for all models.
  • Liquid Pipe Sizes:
    • FDKR200AV16: 1/2"
    • FDKR300AV16: 1/2"
    • FDKR400AV16: 5/8"
  • Gas Pipe Sizes:
    • FDKR200AV16: 7/8"
    • FDKR300AV16: 1-1/8"
    • FDKR400AV16: 1-1/8"
  • Refrigerant Charge (kg/7.5m pipe length):
    • FDKR200AV16: 4.0
    • FDKR300AV16: 4.2
    • FDKR400AV16: 7.6
  • Additional Charge (kg/meter): 0.09 for 1/2" liquid pipe, 0.114 for 5/8" liquid pipe.
  • Oil Refill Charge (Itr/30m pipe length):
    • FDKR200AV16: 1.656
    • FDKR300AV16: 2.395
    • FDKR400AV16: 2.632
  • Operating Range (Cooling Only):
    • Indoor Temperature (DB): 19 to 35°C
    • Indoor Humidity: 80% or below
    • Indoor Temperature (WB): 14 to 24°C
    • Outdoor Temperature (DB): 19 to 52°C

Usage Features:

  • Remote Controller: The unit is operated via a remote controller with an LCD display.
  • Temperature Setting: Users can set the temperature between 16°C and 32°C using "UP" or "DOWN" keys.
  • Operating Modes: Supports Cool Mode and Fan Mode.
  • Fan Speed: Offers LOW/MED/HIGH fan speeds, with automatic selection in cool mode based on room temperature.
  • Menu Mode: Provides options for Key Pad Lock, Clock Setting, and Factory Reset.
    • Key Pad Lock: Prevents accidental changes to settings.
    • Clock Setting: Allows users to set the current time and day.
    • Factory Reset: Resets settings to default (Temp 24°C, Cool Mode, High Fan Speed, clears all programmed timers).
  • RESET/CANCEL Key: Used to reset or cancel the current operation.
  • RIGHT/LEFT Keys: Used to move the cursor or navigate through options.
  • TIMER Function: Allows programming of ON-Timers and OFF-Timers for specific days of the week (MO, TU, WE, TH, FR, SA, SU) or a "Daily" setting.
  • ENERGY SAVER Mode: Available in cool mode, it automatically sets the temperature to 26°C and fan speed to Medium to optimize energy consumption. It can be cancelled by changing the mode, entering standby, or pressing the energy saver key again.
  • ON/OFF SWITCH: Used to power the unit on or off.
  • AUTO RANDOM RE-START FUNCTION: In case of a power cut, the unit automatically resumes the last operating mode when power is restored (if this feature is applicable to the unit).
  • Safety Precautions: The manual emphasizes numerous safety precautions, including proper grounding, installation of an earth leakage breaker, correct wiring, avoiding flammable gases, proper drainage, and using dedicated power supplies.
  • Refrigerant Handling: Strict precautions for R410A refrigerant are outlined, emphasizing cleanliness, dryness, and tight sealing of the system. Only R410A-specific tools should be used.
  • Compressor Protection: Scroll compressors have internal discharge temperature protectors that trip and lock out the compressor for 30 minutes if temperatures become dangerously high, preventing damage.

Maintenance Features:

  • Indoor Air Filter Cleaning:
    • Remove dust with a vacuum cleaner or wash in lukewarm water (below 40°C) with a neutral cleaning detergent.
    • Rinse well and dry before reinstallation.
    • Do not use gasoline, volatile substances, or chemicals.
    • Recommended cleaning frequency: At least once every 2 weeks, or more frequently if necessary.
  • Indoor Unit Cleaning:
    • Clean dirt/dust on the grille or panel with a soft cloth soaked in lukewarm water (below 40°C) and a neutral detergent solution.
    • Do not use gasoline, volatile substances, or chemicals.
    • Recommended cleaning frequency: At least once every 2 weeks, or more frequently if necessary.
  • Drainage Check: After installation, a water drainage test must be conducted to ensure smooth flow.
  • System Checks: Regular checks for unit stability, leak-proof piping, proper wiring, and smooth drainage are recommended.
  • Oil Refill Charge Guidelines: Procedures for removing remaining oil from the compressor and refilling with fresh oil are provided in case of significant oil spill/loss due to leakage. The quality of existing oil should be checked before refilling.
  • Troubleshooting Guide: A comprehensive list of malfunction codes (e.g., A5, A8, C4, C9, E3, E4, E5, E6, F3, H9, J3, J5, J6, L2, L4, L5, LC, P1, PJ, U1, U4, U5) with corresponding descriptions and measures to address common issues.
  • Professional Service: The manual strongly advises consulting a qualified installer or local dealer for installation, repairs, maintenance, relocation, and in case of persistent faults or abnormal operation.
  • Power Management: Turn off the main power switch for prolonged periods of non-use to save energy. When resuming operation, turn it on 6 hours prior for smooth running.
  • EXV Wire Insulation: Ensure the EXV wire insulation tube opening is always directed downward to prevent water droplets from entering the tube during field installations.

Daikin FDKR200AV16 Specifications

General IconGeneral
BrandDaikin
ModelFDKR200AV16
CategoryAir Conditioner
LanguageEnglish

Related product manuals