Dimensions EDUS041502
10 Split Type Air Conditioners FTK(X)-N Series
4. Dimensions
4.1 Indoor Unit
4.1.1 Cooling Only
FTK09/12NMVJU
FTK18NMVJU
30-5/16
(
770 mm
)
21-1/8
(
536.6 mm
)
1-15/16
(
50 mm
)
MIN
9/16
(
14.6 mm
)
1-7/8
(
48 mm
)
1-15/16
(
50 mm
)
MIN
5-3/16
(
132 mm
)
1-7/8
(
48 mm
)
5/16
(
7.9 mm
)
4-9/16
(
116.5 mm
)
1-1/16
(
27 mm
)
13/16
(
20 mm
)
8-7/8
(
225 mm
)
1-3/16
(
30 mm
)
MIN
11-1/4
(
285 mm
)
8-3/4
(
223 mm
)
30-5/16
(
770 mm
)
11-1/4
(
285 mm
)
1-3/4
(
44.5 mm
)
7-1/16
(
180 mm
)
45˚
45˚
1-7/8
(
48 mm
)
1-3/4
(
44.5 mm
)
LIQUID PIPE
INDOOR UNIT ON/OFF SWITCH
DRAIN HOSE
GAS PIPE
SIGNAL RECEIVER
5˚
50˚
DRY
UP/DOWN
(
AUTOMATIC
)
REAR
FAN
FLAPS
OPERATION LAMP
BOTTOM
STANDARD LOCATIONS OF WALL HOLES
COOLING
TIMER LAMP
50˚
0˚
RIGHT
65˚
5˚
SIGNAL TRANSMITTER
LEFT
AIR FLOW
(
INDOOR
)
REQUIRED SPACE
BLADE ANGLE
THE MARK
(→)
SHOWS PIPING DIRECTION
FRONT PANEL FIXING SCREWS
(
INSIDE
)
INCLUDING
MOUNTING PLATE
GENERAL RATING
NAME PLATE
TERMINAL BLOCK
WITH EARTH
TERMINAL
(
INSIDE
)
UP AND DOWN WIND DIRECTION
CONTROL BLADE MOVABLE RANGE
ROOM TEMP. THERMISTOR
(
INSIDE
)
MODEL NAME
PLATE
WIRELESS REMOTE CONTROLLER
(
ARC480A9
)
RIGHT/LEFT
(
MANUAL
)
(
SPACE FOR
MAINTENANCE
)
(
SPACE FOR
MAINTENANCE
)
(
SPACE FOR
PERFORMANCE
)
ABOUT 14-9/16
(
370 mm
)
ABOUT 13
(
330 mm
)
ABOUT 15-3/8
(
390 mm
)
GAS PIPE
φ
3/8
(φ
9.5 mm
)
CuT
(
THE LENGTH OF PIPE OUTSIDE
THE UNIT: ABOUT 14-3/16
(
360 mm
))
LIQUID PIPE
φ
1/4
(φ
6.4 mm
)
CuT
(
THE LENGTH OF PIPE OUTSIDE
THE UNIT: ABOUT 16-1/8
(
410 mm
))
DRAIN HOSE
(
CONNECTING PART
I.D.
φ
9/16
(φ
14 mm
)
O.D.
φ
5/8
(φ
16 mm
)
(
THE HOSE LENGTH OF OUTSIDE
THE UNIT IS ABOUT 18-1/2
(
470 mm
))
WALL HOLE FOR EMBEDDED PIPING
φ
2-9/16
(φ
65 mm
)
HOLE
WALL HOLE
φ
2-9/16
(φ
65 mm
)
HOLE
3D091705
1-3/4
(
44.5mm
)
1-3/16
(
30mm
)
MIN
11-5/8
(
295mm
)
10-3/8
(
263mm
)
29-3/8
(
746mm
)
7-1/16
(
180mm
)
39
(
990mm
)
ABOUT 14-3/16
(
360mm
)
ABOUT 15-3/4
(
400mm
)
ABOUT 17-5/16
(
440mm
)
ABOUT 18-1/8
(
460mm
)
5
(
126.5mm
)
1-7/8
(
48mm
)
39
(
990mm
)
5/16
(
7.9mm
)
ABOUT 14-3/8
(
365mm
)
1-15/16
(
50mm
)
MIN
1-15/16
(
50mm
)
MIN
10-7/16
(
265mm
)
1/2
(
12mm
)
11-5/8
(
295mm
)
1-7/8
(
48mm
)
9/16
(
14.6mm
)
1-3/4
(
44.5mm
)
ABOUT 17-3/4
(
450mm
)
2-3/8
(
60mm
)
13/16 (20mm)
45˚
45˚
THE MARK
(→)
SHOWS PIPING DIRECTION
REAR
TIMER LAMP
RIGHT/LEFT
(
MANUAL
)
REQUIRED SPACE
DRAIN HOSE
55˚
LIQUID PIPE φ1/4
(
φ6.4mm
)
CuT
GAS PIPE φ1/2
(
φ12.7mm
)
CuT
RIGHT
65˚
UP/DOWN
(
AUTOMATIC
)
15˚
SIGNAL TRANSMITTER
80˚
AIR FLOW
(
INDOOR
)
OPERATION LAMP
10˚
MODEL NAME PLATE
BLADE ANGLES
BOTTOM
INDOOR UNIT ON/OFF SWITCH
FANCOOLING, DRY
STANDARD LOCATIONS OF WALL HOLES
30˚
LEFT
SIGNAL RECEIVER
25˚
LIQUID PIPE
GAS PIPE
FLAPS
70˚
WALL HOLE FOR EMBEDDED PIPING
φ3-1/8
(
φ80mm
)
HOLE
WALL HOLE
φ3-1/8
(
φ80mm
)
HOLE
DRAIN HOSE
(
CONNECTING PART
I.D. φ9/16
(
φ14mm
)
O.D. φ5/8
(
φ16mm
)
(SPACE FOR
MAINTENANCE)
(SPACE FOR
PERFORMANCE)
(SPACE FOR
MAINTENANCE)
GENERAL RATING
NAME PLATE
TERMINAL BLOCK
WITH EARTH
TERMINAL
(
INSIDE
)
UP AND DOWN WIND DIRECTION
CONTROL BLADE MOVABLE RANGE
ROOM TEMP. THERMISTOR
(
INSIDE
)
FRONT GRILLE FIXING SCREWS
(
INSIDE
)
()
INCLUDING
MOUNTING PLATE
WIRELESS REMOTE CONTROLLER
(
ARC480A9
)
3D091781