Capacity Tables EDUS041502
40 Split Type Air Conditioners FTK(X)-N Series
FTX24NMVJU + RX24NMVJU
60 Hz, 208 V
Cooling
Heating
AFR 20.2
BF 0.27
Temp: Celsius
TC, SHC, PI: kW
INDOOR OUTDOOR TEMPERATURE (°CDB)
EWB EDB 20 25 30 32 35 40
°C °C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
14.020.06.054.471.296.054.471.435.774.331.555.664.271.605.494.191.685.204.041.71
16.022.06.644.541.316.354.401.436.064.271.565.944.211.615.774.131.685.484.001.72
18.025.06.924.741.326.634.611.446.354.491.576.234.431.626.064.361.695.774.241.73
19.426.77.074.991.326.784.861.456.494.741.576.374.691.62
6.20 4.62 1.70 5.91 4.50 1.73
22.030.07.494.801.337.214.691.466.924.591.586.804.541.636.634.481.716.344.371.74
24.032.07.784.671.347.494.571.467.204.471.597.094.431.646.914.381.716.634.281.75
Temp: Fahrenheit
TC, SHC: kBtu/h
PI: kW
INDOOR OUTDOOR TEMPERATURE (°FDB)
EWB EDB 68 77 86 90 95 104
°F °F TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
57.2 68.0 20.65 15.25 1.29 20.65 15.25 1.43 19.70 14.77 1.55 19.31 14.57 1.60 18.72 14.28 1.68 17.73 13.80 1.71
60.8 71.6 22.65 15.49 1.31 21.66 15.02 1.43 20.68 14.55 1.56 20.28 14.37 1.61 19.69 14.09 1.68 18.71 13.64 1.72
64.4 77.0 23.62 16.18 1.32 22.64 15.74 1.44 21.65 15.30 1.57 21.26 15.13 1.62 20.67 14.87 1.69 19.68 14.45 1.73
67.0 80.0 24.11 17.01 1.32 23.12 16.59 1.45 22.14 16.17 1.57 21.75 16.01 1.62
21.20 15.76 1.70 20.17 15.35 1.73
71.6 86.0 25.57 16.39 1.33 24.59 16.01 1.46 23.60 15.64 1.58 23.21 15.50 1.63 22.62 15.28 1.71 21.63 14.92 1.74
75.2 89.6 26.55 15.94 1.34 25.56 15.60 1.46 24.58 15.26 1.59 24.18 15.13 1.64 23.59 14.93 1.71 22.61 14.60 1.75
AFR 21.1
Temp: Celsius
TC, PI: kW
INDOOR OUTDOOR TEMPERATURE (°CWB)
EDB 15 –10 –5 0 6 10
°C TC PI TC PI TC PI TC PI TC PI TC PI
15.0 3.35 1.29 4.02 1.36 4.70 1.43 6.32 1.87 7.27 1.96 7.91 2.03
21.1 3.14 1.33 3.82 1.40 4.49 1.46 6.08 1.91
7.03 2.01 7.67 2.08
22.0 3.06 1.34 3.73 1.41 4.41 1.48 5.98 1.93 6.93 2.03 7.57 2.09
24.0 2.98 1.36 3.65 1.43 4.33 1.49 5.88 1.95 6.84 2.05 7.47 2.11
25.0 2.94 1.37 3.61 1.43 4.28 1.50 5.83 1.96 6.79 2.06 7.42 2.12
27.0 2.85 1.38 3.53 1.45 4.20 1.51 5.74 1.97 6.69 2.07 7.33 2.14
Temp: Fahrenheit
TC: kBtu/h
PI: kW
INDOOR OUTDOOR TEMPERATURE (°FWB)
EDB 5 14 23 32 43 50
°F TC PI TC PI TC PI TC PI TC PI TC PI
59.0 11.42 1.29 13.73 1.36 16.03 1.43 21.56 1.87 24.81 1.96 26.98 2.03
70.0 10.72 1.33 13.02 1.40 15.32 1.46 20.74 1.91
24.00 2.01 26.15 2.08
71.6 10.44 1.34 12.74 1.41 15.04 1.48 20.40 1.93 23.66 2.03 25.82 2.09
75.2 10.16 1.36 12.46 1.43 14.76 1.49 20.07 1.95 23.32 2.05 25.49 2.11
77.0 10.02 1.37 12.32 1.43 14.62 1.50 19.91 1.96 23.16 2.06 25.33 2.12
80.6 9.73 1.38 12.04 1.45 14.34 1.51 19.58 1.97 22.83 2.07 24.99 2.14