Si18-201 For BPMK928B42 · 43
Removal Procedure 315
1.3 Removal of Motorized Valve
Procedure Warning Be sure to turn off all power supplies before disassembling work.
Step Procedure Points
1. Detaching the bottom
panel
1
Loosen the two
keyhole-provided
screws and remove the
two other screws from
the electrical mounting
plate.
2. Removing the motorized
valve coil
"
When reassembling, make
sure the motorized valve coil
spring clicks and feels
caught.
1
Slide the motorized
valve coil to the right
and take it out.
3. Undoing the clamp
"
The plain, red, blue and
yellow markings are
provided from the front
bottom.
1
Remove the harness
clamp from the side.

Table of Contents