REMOVAL
PROCEDURE
SERVICE MANUAL
Indoor Unit
Inverter / Non-Inverter
Wall Mounted Type
2.0/2.5/3.5 kW Class
9000/13000 Btu/h Class
Si041251EC
Question and Answer IconNeed help?

Do you have a question about the Daikin FTKV35NVM and is the answer not in the manual?

Daikin FTKV35NVM Specifications

General IconGeneral
Cooling Capacity3.5 kW
Heating Capacity4.0 kW
InverterYes
RefrigerantR32
Power Supply230V, 50Hz, 1 Phase
Energy Efficiency Ratio (Cooling)3.5

Summary

Air Filters

1. Air Filters

Procedure for removing the primary and secondary air filters, including specific instructions for titanium apatite filters.

Electrical Box

5. Electrical Box

Procedure for removing the electrical box, involving wire fixtures, terminal boards, and connectors.

PCBs

6. PCBs

Procedure for removing the shield plate and releasing the indoor heat exchanger thermistor and ground wire.

5. Remove the signal receiver PCB.

Steps to unfasten hooks and disconnect connectors to remove the signal receiver PCB.

6. Remove the INTELLIGENT EYE sensor PCB.

Procedure for removing the INTELLIGENT EYE sensor PCB, involving twisting and unfastening hooks.

Drain Pan Unit and Swing Motor

Fan Motor

8. Fan Motor

Procedure for removing the fan motor, including releasing lead wires and unfastening fixing plate.

Fan Rotor

10. Fan Rotor

Procedure for removing the fan rotor and fan motor, including side plates and fixing plates.

Indoor Heat Exchanger

9. Indoor Heat Exchanger

Procedure for removing the indoor heat exchanger, involving screws, pipings, and unit detachment.

General Warnings and Cautions

Safety and Product Care Warnings

Important safety instructions for installation, usage, and precautions against product corrosion.