Specifications Si18-201
20 Specifications
Refer to Engineering Data Book.
"
5.0kW Class
50Hz 220-230-240V / 60Hz 220-230V
Model FTKD50JVE FTKD50JVEA9
Rating Capacity kW 5.0
Front Panel Color Almond White
Air Flow Rates
m³/min
H 12.9
M 11.4
L9.9
cfm
H 455
M 402
L 349
Fan
Type Cross Flow Fan
Motor Output W 54
Speed Steps 5 Steps and Auto
Air Filter Removal / Washable / Mildew Proof
Running Current
(Rated) A 0.19-0.18-0.17 / 0.19-0.18
Power Consumption
(Rated) W 40
Power Factor
% 95.7-96.7-98.0 / 95.7-96.7
Temperature Control Microcomputer Control
Dimensions (H×W×D) mm 298×1,050×190
Package Dimensions (W×D×H) mm 1,183×367×289
Weight kg 12
Gross Weight kg 16
Operation Sound dBA
H44
M40
L35
Heat Insulation Both Liquid and Gas Pipes
Piping
Connection
Liquid mm
φ
6.4
Gas mm
φ
12.7
Drain mm
φ
18.0
Drawing No. 3D027863A 3D027860C
"
6.0kW Class
50Hz 220-230-240V / 60Hz 220-230V
Model FTKD60JVE FTKD60JVEA
Rating Capacity kW 6.0
Front Panel Color Almond White
Air Flow Rates
m³/min
H 13.6
M 12.0
L 10.4
cfm
H 480
M 424
L 367
Fan
Type Cross Flow Fan
Motor Output W 54
Speed Steps 5 Steps and Auto
Air Filter Removal / Washable / Mildew Proof
Running Current
(Rated) A 0.21-0.20-0.19 / 0.21-0.20
Power Consumption
(Rated) W 45
Power Factor
% 97.4-97.8 -98.7 / 97.4-97.8
Temperature Control Microcomputer Control
Dimensions (H×W×D) mm 298×1,050×190
Package Dimensions (W×D×H) mm 1,183×367×289
Weight kg 12
Gross Weight kg 16
Operation Sound dBA
H45
M41
L37
Heat Insulation Both Liquid and Gas Pipes
Piping
Connection
Liquid mm
φ
6.4
Gas mm
φ
15.9
Drain mm
φ
18.0
Drawing No. 3D027864 3D027861
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414