Si18-201 Installation
Caution Before Operation 345
(C) Where there are obstacles on both suction and discharge sides:
Pattern 1 Where the obstacles on the discharge side is higher than the unit:
No obstacle above
Obstacle above, too
The relations between H, A and L are as follows:
Close the bottom of the installation frame to prevent the discharged
air from being bypassed.
Pattern 2 Where the obstacle on the discharge side is lower than the unit:
No obstacle above
Obstacle above, too
The relations between H, A and L are as follows:
Close the bottom of the installation frame to prevent the discharged
air from being bypassed.
(D) Multiple rows of series installation (on the rooftop, etc.)
LA
L H
0 < L 1/2H 750
1/2H < L 1000
H
<
L Set the stand as: L H
LA
L H
0 < L 1/2H 100
1/2H < L 200
H < L Set the stand as: L H