Fan Rotor Si041251EC
20 Removal Procedure
10.Fan Rotor
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Step Procedure Points
1
2
Remove the 2 screws
of the right side plate.
Release the fan motor
lead wire from the
hooks and remove the
right side plate.
When reassembling the fan
motor and the fan rotor,
provide as much as 5 mm
(0.2 inch) of play between
the side face of the rotor and
the bottom frame.
(1) Insert the fan motor with
approx. 5 mm (0.2 inch) left.
(2) Tighten the screw until it
stops. Then give the screw
one more turn.
(3) Rotate the fan rotor and
confirm the fan motor and
the fan rotor are installed
appropriately.
(4) Tighten the screw
completely if appropriate.
(5) If not appropriate, go back to
(1).
3
4
5
6
Remove the 2 screws
of the fan motor fixing
plate.
Unfasten the hook (a)
of the fan motor fixing
plate and unfasten the
hook (b).
Remove the fan motor
fixing plate.
Loosen the screw and
remove the fan motor
and the fan rotor.
(R17212)
Right side plate
Fan motor lead wire
Hook
5 mm (0.2 inch)
Side face of rotor
(R18879)
Side face of
bottom frame
(R9582)
(R17929)
Hook (a)
Hook (b)
Fan motor
fixing plate
Fan motor
Fan rotor
Screw
(R19302)