Specifications ED041204
12 Split Type Air Conditioners FTK(X)S-L Series
50 Hz, 220 - 230 - 240 V / 60 Hz, 220 - 230 V
Note:
The data are based on the conditions shown in the table below.
Model
Indoor Unit FTXS50LVMA FTXS60LVMA
Outdoor Unit
RXS50LVMA RXS60LVMA
Cooling Heating Cooling Heating
Capacity
Rated (Min. ~ Max.)
kW 5.0 (1.7 ~ 6.0) 6.0 (1.7 ~ 7.7) 6.0 (1.7 ~ 6.7) 7.0 (1.7 ~ 8.0)
Btu/h 17,100 (5,800 ~ 20,500) 20,500 (5,800 ~ 26,300) 20,500 (5,800 ~ 22,900) 23,900 (5,800 ~ 27,300)
kcal/h 4,300 (1,460 ~ 5,160) 5,160 (1,460 ~ 6,620) 5,160 (1,460 ~ 5,760) 6,020 (1,460 ~ 6,880)
Moisture Removal L/h 2.9 — 3.9 —
Running Current (Rated) A 6.1 - 5.8 - 5.6 / 6.1 - 5.8 6.8 - 6.5 - 6.2 / 6.8 - 6.5 7.8 - 7.4 - 7.1 / 7.8 - 7.4 7.9 - 7.6 - 7.3 / 7.9 - 7.6
Power Consumption
Rated (Min. ~ Max.)
W 1,320 (440 ~ 1,920) 1,470 (400 ~ 2,150) 1,690 (440 ~ 2,230) 1,730 (400 ~ 2,360)
Power Factor %
98.4 - 99.0 - 98.2 /
98.4 - 99.0
98.3 - 98.3 - 98.8 /
98.3 - 98.3
98.5 - 99.3 - 99.2 /
98.5 - 99.3
99.5 - 99.0 - 98.7 /
99.5 - 99.0
EER (Cooling) / COP (Heating)
Rated (Min. ~ Max.)
W/W 3.79 (3.86 ~ 3.13) 4.08 (4.25 ~ 3.58) 3.55 (3.86 ~ 3.00) 4.05 (4.25 ~ 3.39)
Piping
Connections
Liquid mm φ 6.4 φ 6.4
Gas mm φ 12.7 φ 12.7
Drain mm φ 16.0 φ 16.0
Heat Insulation Both Liquid and Gas Pipes Both Liquid and Gas Pipes
Max. Interunit Piping Length m 30 30
Max. Interunit Height Difference m 20 20
Chargeless m 10 10
Amount of Additional Charge of Refrigerant g/m 20 20
Indoor Unit FTXS50LVMA FTXS60LVMA
Front Panel Colour White White
Airflow Rate
H
m³/min
(cfm)
18.3 (646) 19.4 (685) 19.2 (678) 21.2 (749)
M 14.9 (526) 16.1 (568) 15.5 (547) 16.7 (590)
L 11.6 (410) 12.7 (448) 11.9 (420) 12.4 (438)
SL 10.8 (381) 11.7 (413) 10.7 (378) 11.2 (395)
Fan
Type Cross Flow Fan Cross Flow Fan
Motor Output W 48 48
Speed Steps 5 Steps, Quiet, Auto 5 Steps, Quiet, Auto
Air Direction Control Right, Left, Horizontal, Downwards Right, Left, Horizontal, Downwards
Air Filter Removable / Washable / Mildew Proof Removable / Washable / Mildew Proof
Running Current (Rated) A
0.30 - 0.29 - 0.28 /
0.30 - 0.29
0.32 - 0.31 - 0.30 /
0.32 - 0.31
0.48 - 0.46 - 0.45 /
0.48 - 0.46
0.55 - 0.53 - 0.51 /
0.55 - 0.53
Power Consumption (Rated) W 38 - 38 - 38 / 38 - 38 40 - 40 - 40 / 40 - 40 60 - 60 - 60 / 60 - 60 68 - 68 - 68 / 68 - 68
Power Factor %
57.6 - 57.0 - 56.5 /
57.6 - 57.0
56.8 - 56.1 - 55.6 /
56.8 - 56.1
56.8 - 56.7 - 55.6 /
56.8 - 56.7
56.2 - 55.8 - 55.6 /
56.2 - 55.8
Temperature Control Microcomputer Control Microcomputer Control
Dimensions (H × W × D) mm 340 × 1,050 × 248 340 × 1,050 × 248
Packaged Dimensions (H × W × D) mm 331 × 1,160 × 429 331 × 1,160 × 429
Weight (Mass) kg 14 14
Gross Weight (Gross Mass) kg 20 21
Sound Pressure
Level
H / M / L / SL dB(A) 46 / 40 / 35 / 32 45 / 39 / 33 / 30 48 / 42 / 36 / 33 48 / 41 / 33 / 30
Sound Power
Level
HdB62616464
Outdoor Unit RXS50LVMA RXS60LVMA
Casing Colour Ivory White Ivory White
Compressor
Type Hermetically Sealed Swing Type Hermetically Sealed Swing Type
Model 2YC36BXD 2YC36BXD
Motor Output W 1,100 1,100
Refrigerant Oil
Type FVC50K FVC50K
Charge L 0.650 0.650
Refrigerant
Type R-410A R-410A
Charge kg 1.8 1.8
Airflow Rate
H
m³/min
(cfm)
48.5 (1,713) 39.8 (1,405) 50.4 (1,780) 40.9 (1,444)
SL 41.6 (1,469) 37.0 (1,306) 42.3 (1,494) 37.6 (1,328)
Fan
Type Propeller Propeller
Motor Output W 53 53
Running Current (Rated) A
5.9 - 5.6 - 5.4 /
5.9 - 5.6
6.6 - 6.3 - 6.0 /
6.6 - 6.3
7.5 - 7.1 - 6.8 /
7.5 - 7.1
7.6 - 7.3 - 7.0 /
7.6 - 7.3
Power Consumption (Rated) W
1,282 - 1,282 - 1,282 /
1,282 - 1,282
1,430 - 1,430 - 1,430 /
1,430 - 1,430
1,630 - 1,630 - 1,630 /
1,630 - 1,630
1,662 - 1,662 - 1,662 /
1,662 - 1,662
Power Factor %
98.8 - 99.5 - 98.9 /
98.8 - 99.5
98.5 - 98.7 - 99.3 /
98.5 - 98.7
98.8 - 99.8 - 99.9 /
98.8 - 99.8
99.4 - 99.0 - 98.9 /
99.4 - 99.0
Starting Current A 6.8 7.9
Dimensions (H × W × D) mm 735 × 825 × 300 735 × 825 × 300
Packaged Dimensions (H × W × D) mm 792 × 960 × 390 792 × 960 × 390
Weight (Mass) kg 46 46
Gross Weight (Gross Mass) kg 52 52
Sound Pressure
Level
H / SL dB(A) 47 / 44 48 / 45 49 / 46 49 / 46
Sound Power
Level
HdB61626363
Drawing No. 3D075821 3D075822
Conversion Formulae
kcal/h = kW × 860
Btu/h = kW × 3412
cfm = m³/min × 35.3
Cooling Heating Piping Length
Indoor ; 27°CDB / 19°CWB
Outdoor ; 35°CDB / 24°CWB
Indoor ; 20°CDB
Outdoor ; 7°CDB / 6°CWB
7.5 m