ED041204 Electric Characteristics
Split Type Air Conditioners FTK(X)S-L Series 59
10.Electric Characteristics
3D075509A
3D075523
Indoor unit Outdoor unit
Power supply COMP OFM IFM
Hz - Volts Voltage range MCA MFA RHz RLA W FLA W FLA
FTKS20LVMA
FTXS20LVMA
RKS20LVMA
RXS20LVMA
50 - 220
MAX. 50 Hz, 264 V
MIN. 50 Hz, 198 V
8.0 10
34.0
2.1
33 0.17 23 0.12
50 - 230 2.0
50 - 240 1.9
60 - 220
MAX. 60 Hz, 253 V
MIN. 60 Hz, 198 V
2.1
60 - 230 2.0
FTKS25LVMA
FTXS25LVMA
RKS25LVMA
RXS25LVMA
50 - 220
MAX. 50 Hz, 264 V
MIN. 50 Hz, 198 V
8.0 10 44.0
2.6
33 0.17 23 0.12
50 - 230 2.5
50 - 240 2.4
60 - 220
MAX. 60 Hz, 253 V
MIN. 60 Hz, 198 V
2.6
60 - 230 2.5
FTKS35LVMA
FTXS35LVMA
RKS35LVMA
RXS35LVMA
50 - 220
MAX. 50 Hz, 264 V
MIN. 50 Hz, 198 V
8.8 10
66.0
3.9
33 0.17 23 0.12
50 - 230 3.7
50 - 240 3.5
60 - 220
MAX. 60 Hz, 253 V
MIN. 60 Hz, 198 V
3.9
60 - 230 3.7
FTKS46LVMA
FTXS46LVMA
RKS46LVMA
RXS46LVMA
50 - 220
MAX. 50 Hz, 264 V
MIN. 50 Hz, 198 V
9.0 10 59.7
5.3
53 0.20 23 0.12
50 - 230 5.0
50 - 240 4.8
60 - 220
MAX. 60 Hz, 253 V
MIN. 60 Hz, 198 V
5.3
60 - 230 5.0
FTKS50LVMA
FTXS50LVMA
RKS50LVMA
RXS50LVMA
50 - 220
MAX. 50 Hz, 264 V
MIN. 50 Hz, 198 V
13.8 15 61.0
5.6
53 0.20 48 0.23
50 - 230 5.3
50 - 240 5.1
60 - 220
MAX. 60 Hz, 253 V
MIN. 60 Hz, 198 V
5.6
60 - 230 5.3
FTKS60LVMA
FTXS60LVMA
RKS60LVMA
RXS60LVMA
50 - 220
MAX. 50 Hz, 264 V
MIN. 50 Hz, 198 V
13.8 15 72.0
7.3
53 0.20 48 0.23
50 - 230 6.9
50 - 240 6.6
60 - 220
MAX. 60 Hz, 253 V
MIN. 60 Hz, 198 V
7.3
60 - 230 6.9
FTKS71LVMA
FTXS71LVMA
RKS71LVMA
RXS71LVMA
50 - 220
MAX. 50 Hz, 264 V
MIN. 50 Hz, 198 V
17.5 20 49.9
9.2
66 0.34 48 0.23
50 - 230 8.8
50 - 240 8.4
60 - 220
MAX. 60 Hz, 253 V
MIN. 60 Hz, 198 V
9.2
60 - 230 8.8
FTXS85LVMA RXS85LVMA
50 - 220
MAX. 50 Hz, 264 V
MIN. 50 Hz, 198 V
19.5 20 62.0
11.4
200 0.76 64 0.29
50 - 230 10.9
50 - 240 10.4
60 - 220
MAX. 60 Hz, 253 V
MIN. 60 Hz, 198 V
11.4
60 - 230 10.9
FTXS95LVMA RXS95LVMA
50 - 220
MAX. 50 Hz, 264 V
MIN. 50 Hz, 198 V
19.5 20 66.4
12.8
200 0.76 64 0.29
50 - 230 12.2
50 - 240 11.7
60 - 220
MAX. 60 Hz, 253 V
MIN. 60 Hz, 198 V
12.8
60 - 230 12.2
Symbols: Note:
MCA : Min. circuit amps (A)
1. RLA is based on the following conditions.
Indoor temp. 27°CDB / 19°CWB
Outdoor temp. 35°CDB.
2. Maximum allowable voltage variation between phases is 2%.
3. Select wire size based on the larger value of MCA.
4. Instead of fuse, use circuit breaker.
5. Be sure to install an earth leak detector. (One that can handle
higher harmonics.)
(This unit uses an inverter, which means that it must be used an
earth leak detector capable handling high harmonics in order to
prevent malfunctioning of the earth leak detector itself.)
MFA : Max. fuse amps (A)
RHz : Rated operating frequency (Hz)
RLA : Rated load amps (A)
OFM : Outdoor fan motor
IFM : Indoor fan motor
W : Fan motor rated output (W)
FLA : Full load amps (A)