ED041204 Sound Level
Split Type Air Conditioners FTK(X)S-L Series 51
9.2 Indoor Unit
9.2.1 Cooling Only
FTKS20LVMA FTKS25LVMA
FTKS35LVMA FTKS46LVMA
FTKS50LVMA FTKS60LVMA
FTKS71LVMA
POWER SOURCE
JIS STANDARD
OPERATING CONDITIONS
OCTAVE BAND SOUND PRESSURE LEVEL
dB
(
0dB=0.0002
µ
bar
)
70
60
20
30
50
40
THRESHOLD HEARING
APPROXIMATE
FOR CONTINUOUS
NOISE
63 125
OCTAVE BAND CENTER FREQUENCY
(
Hz
)
250 500 1000 2000 4000 8000
OVER ALL
(
dB
)
SCALE
A
(
B.G.N IS ALREADY RECTIFIED
)
NC-20
NC-50
NC-40
NC-60
NC-70
NC-30
38
50/60Hz
220-240/220-230V
(H)
50/60Hz
220-240/220-230V
(L)
25
220-240/220-230V 50/60Hz
50/60Hz 220-240/220-230V(H)
50/60Hz 220-240/220-230V(L)
Cooling
STANDARD EXTERNAL STATIC PRESSURE
4D069097B
NC-70
NC-60
NC-50
NC-40
NC-30
NC-20
50/60Hz 220-240/220-230V(H)
50/60Hz 220-240/220-230V(L)
STANDARD EXTERNAL STATIC PRESSURE
50/60Hz
220-240/220-230V
(H)
40
50/60Hz
220-240/220-230V
(L)
25
POWER SOURCE
JIS STANDARD
OPERATING CONDITIONS
OVER ALL
(
dB
)
SCALE
A
(
B.G.N IS ALREADY RECTIFIED
)
220-240/220-230V 50/60Hz
OCTAVE BAND SOUND PRESSURE LEVEL
dB
(
0dB=0.0002
µ
bar
)
70
60
20
30
50
40
63 125
OCTAVE BAND CENTER FREQUENCY
(
Hz
)
250 500 1000 2000 4000 8000
THRESHOLD HEARING
APPROXIMATE
FOR CONTINUOUS
NOISE
4D075889
NC-70
NC-60
NC-50
NC-40
NC-30
NC-20
50/60Hz 220-240/220-230V(H)
50/60Hz 220-240/220-230V(L)
STANDARD EXTERNAL STATIC PRESSURE
50/60Hz
220-240/220-230V
(H)
42
50/60Hz
220-240/220-230V
(L)
26
POWER SOURCE
JIS STANDARD
OPERATING CONDITIONS
OVER ALL
(
dB
)
SCALE
A
(
B.G.N IS ALREADY RECTIFIED
)
220-240/220-230V 50/60Hz
OCTAVE BAND SOUND PRESSURE LEVEL
dB
(
0dB=0.0002
µ
bar
)
70
60
20
30
50
40
63 125
OCTAVE BAND CENTER FREQUENCY
(
Hz
)
250 500 1000 2000 4000 8000
THRESHOLD HEARING
APPROXIMATE
FOR CONTINUOUS
NOISE
4D075890
NC-70
NC-60
NC-50
NC-40
NC-30
NC-20
50/60Hz 220-240/220-230V(H)
50/60Hz 220-240/220-230V(L)
STANDARD EXTERNAL STATIC PRESSURE
50/60Hz
220-240/220-230V
(H)
44
50/60Hz
220-240/220-230V
(L)
35
POWER SOURCE
JIS STANDARD
OPERATING CONDITIONS
OVER ALL
(
dB
)
SCALE
A
(
B.G.N IS ALREADY RECTIFIED
)
220-240/220-230V 50/60Hz
OCTAVE BAND SOUND PRESSURE LEVEL
dB
(
0dB=0.0002
µ
bar
)
70
60
20
30
50
40
63 125
OCTAVE BAND CENTER FREQUENCY
(
Hz
)
250 500 1000 2000 4000 8000
THRESHOLD HEARING
APPROXIMATE
FOR CONTINUOUS
NOISE
4D075429
NC-70
NC-60
NC-50
NC-40
NC-30
NC-20
OCTAVE BAND SOUND PRESSURE LEVEL
dB
(
0dB=0.0002
µ
bar
)
70
60
20
30
50
40
THRESHOLD HEARING
APPROXIMATE
FOR CONTINUOUS
NOISE
63 125
OCTAVE BAND CENTER FREQUENCY
(
Hz
)
250 500 1000 2000 4000 8000
50/60Hz 220-240/220-230V(H)
50/60Hz 220-240/220-230V(L)
STANDARD EXTERNAL STATIC PRESSURE
50/60Hz
220-240/220-230V
(H)
46
50/60Hz
220-240/220-230V
(L)
35
POWER SOURCE
JIS STANDARD
OPERATING CONDITIONS
OVER ALL
(
dB
)
SCALE
A
(
B.G.N IS ALREADY RECTIFIED
)
220-240/220-230V 50/60Hz
4D075816
NC-70
NC-60
NC-50
NC-40
NC-30
NC-20
50/60Hz 220-240/220-230V(H)
50/60Hz 220-240/220-230V(L)
STANDARD EXTERNAL STATIC PRESSURE
50/60Hz
220-240/220-230V
(H)
48
50/60Hz
220-240/220-230V
(L)
36
POWER SOURCE
JIS STANDARD
OPERATING CONDITIONS
OVER ALL
(
dB
)
SCALE
A
(
B.G.N IS ALREADY RECTIFIED
)
220-240/220-230V 50/60Hz
OCTAVE BAND SOUND PRESSURE LEVEL
dB
(
0dB=0.0002
µ
bar
)
70
60
20
30
50
40
63 125
OCTAVE BAND CENTER FREQUENCY
(
Hz
)
250 500 1000 2000 4000 8000
THRESHOLD HEARING
APPROXIMATE
FOR CONTINUOUS
NOISE
4D075817
NC-70
NC-60
NC-50
NC-40
NC-30
NC-20
50/60Hz 220-240/220-230V(H)
50/60Hz 220-240/220-230V(L)
STANDARD EXTERNAL STATIC PRESSURE
50/60Hz
220-240/220-230V
(H)
51
50/60Hz
220-240/220-230V
(L)
37
POWER SOURCE
JIS STANDARD
OPERATING CONDITIONS
OVER ALL
(
dB
)
SCALE
A
(
B.G.N IS ALREADY RECTIFIED
)
220-240/220-230V 50/60Hz
OCTAVE BAND SOUND PRESSURE LEVEL
dB
(
0dB=0.0002
µ
bar
)
70
60
20
30
50
40
THRESHOLD HEARING
APPROXIMATE
FOR CONTINUOUS
NOISE
63 125
OCTAVE BAND CENTER FREQUENCY
(
Hz
)
250 500 1000 2000 4000 8000
4D075818