C-Series
[Applied Models]
zInverter Multi : Cooling Only
zInverter Multi : Heat Pump
Si12 - 411A

Table of Contents

Other manuals for Daikin FTKS35CVMB8

Questions and Answers:

Daikin FTKS35CVMB8 Specifications

General IconGeneral
Cooling Capacity3.5 kW
Heating Capacity4.0 kW
Power Supply220-240V, 50Hz
RefrigerantR32
Indoor Unit Weight9 kg
TypeSplit System
Outdoor Unit Noise Level48 dB(A)

Summary

Introduction

Safety Cautions

Essential safety precautions for operating and repairing the air conditioner.

Part 1 List of Functions

Cooling Only Models

Detailed list of functions for cooling-only models, categorized by type.

Heat Pump Models

Detailed list of functions for heat pump models, categorized by type.

Part 2 Specifications

Part 3 Printed Circuit Board Connector Wiring Diagram

Printed Circuit Board Connector Wiring Diagram

Diagrams illustrating PCB connectors for system components.

Part 4 Function and Control

Freeze-up Protection Control

Mechanism to prevent indoor heat exchanger freezing during cooling.

Electronic Expansion Valve Control

Control logic for the electronic expansion valve in various modes.

Part 5 System Configuration

Safety Precautions

Critical safety warnings and cautions for installation, operation, and maintenance.

Part 6 Service Diagnosis

Problem Symptoms and Measures

Common issues and their corresponding troubleshooting steps and solutions.

Code Indication on the Remote Controller

Explanation of error codes displayed on the remote controller for fault identification.

Troubleshooting

Detailed troubleshooting steps for indoor unit related issues.

Outdoor Units

Troubleshooting steps for outdoor unit related issues, including LED indications.

Insufficient Gas

Identifying and addressing issues related to insufficient refrigerant gas.

Electronic Expansion Valve Check

Steps to check the electronic expansion valve's operation and conductivity.

Power Transistor Check

Steps for checking the power transistor, including safety measures for live parts.

Part 7 Removal Procedure

Related product manuals