Removal of PCBs Si04-958
16 Removal Procedure
2
Remove the sensor
from the shield plate.
When reassembling, set the
sensor at the position where
it “clicks”. Otherwise, the
sensor is not completely set.
3
Remove the shield
plate by unfastening the
2 hooks.
4
Disconnect the
connector.
[S36]: control PCB
Step
Procedure Points
(R9525)
Sensor Shield plate
(R9526)
Shield plate (rear)
Hook
INTELLIGENT EYE
sensor PCB
(R9527)
[S36]