EasyManua.ls Logo

Daikin FTX25JV1NB User Manual

Daikin FTX25JV1NB
142 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
SIE-86
Table of Contents i
Inverter Pair
FTK(X)-J / RK(X)-J Series
Cooling Only
Indoor Unit
FTK25JV1NB
FTK35JV1NB
Outdoor Unit
RK25JV1NB
RK35JV1NB
Heat Pump
Indoor Unit
FTX25JV1NB
FTX35JV1NB
Outdoor Unit
RX25JV1NB
RX35JV1NB
Si-86.book Page i Friday, June 23, 2000 10:26 AM

Table of Contents

Questions and Answers:

Daikin FTX25JV1NB Specifications

General IconGeneral
BrandDaikin
ModelFTX25JV1NB
CategoryInverter
LanguageEnglish

Summary

Part 2 Printed Circuit Board Connector Wiring Diagram

Part 3 Main Function

Part 4 System Configuration

Safety Precautions for FTK/FTX Models

Essential safety warnings and cautions for installation and use.

Part 5 Service Diagnosis

Caution for Diagnosis

General cautions and guidelines before performing diagnosis.

Troubleshooting with Operation Lamp

Using the operation lamp status for troubleshooting.

Troubleshooting with LED Indication

Diagnosing issues using LED indicators on the outdoor unit.

Problem Symptoms and Measures

Common symptoms and their corresponding troubleshooting measures.

Remote Controller Error Codes

List of error codes displayed on the remote controller and their meanings.

Troubleshooting Indoor Units

Specific troubleshooting steps for indoor unit related faults.

Troubleshooting Outdoor Units

Specific troubleshooting steps for outdoor unit related faults.

Faulty PCB Troubleshooting

Troubleshooting procedures for faulty Printed Circuit Boards.

Operation Shutdown Troubleshooting

Diagnosing shutdowns due to high-pressure or freeze-up protection.

Fan Motor Abnormality Troubleshooting

Troubleshooting issues related to fan motor operation or abnormalities.

Thermistor Error Troubleshooting

Diagnosing operation halts due to thermistor errors or disconnections.

Faulty Indoor Unit PCB Troubleshooting

Troubleshooting steps for a faulty indoor unit PCB.

Indoor Unit PCB Signal Issues

Troubleshooting faulty indoor unit PCB related to signal transmission.

Power Supply & Indoor PCB Faults

Troubleshooting power supply abnormalities and faulty indoor PCBs.

Signal Transmission Error Troubleshooting

Diagnosing signal transmission errors between indoor and outdoor units.

CT Error Troubleshooting

Troubleshooting operation halts due to CT (Current Transformer) errors.

Thermistor Error Troubleshooting (J3,J6,H9)

Troubleshooting thermistor errors or disconnections detected.

Compressor Startup Error Troubleshooting

Diagnosing operation halts due to compressor startup errors.

Output Overcurrent Troubleshooting

Troubleshooting operation halts due to output overcurrent.

Faulty Outdoor Unit PCB Troubleshooting

Troubleshooting steps for a faulty outdoor unit PCB.

Outdoor PCB & Signal Issues

Troubleshooting faulty outdoor PCB and signal transmission circuits.

Input Over Current Troubleshooting

Diagnosing operation halts due to detection of input over current.

Component Check Procedures

Detailed procedures for checking various system components.

Power Transistor Check

Procedure for checking the power transistor's voltage and resistance.

Power Transistor Output Check

Method for measuring power transistor output current and voltage.

Thermistor Resistance Check

Procedure to measure thermistor resistance at different temperatures.

Installation Condition Check

Checking installation conditions like airflow and temperature.

Rectifier Check

Procedure for checking the rectifier's resistance and continuity.

Part 6 Removal Procedure