2 Measure the voltage on the rectifier voltage check terminals (+ and –) on the
main PCB.
Result: The measured voltage MUST be approximately 300~350VDC.
a
A
b
A RXA42~50A unit
a + terminal
b – terminal
a
b
A
A RXA42~50B unit
a + terminal
b – terminal
INFORMATION
When measuring on the front of the main PCB, make sure to locally remove the
protective varnish with the test leads of the multi meter.
Is the measured rectifier voltage
correct?
Action
Yes Perform a check of the power module,
see "Checking procedures"[499].
No Replace the main PCB, see "Repair
procedures"[4108].