User reference guide
Daikin room air conditioner
CTXA15A2V1BW
FTXA20A2V1BW
FTXA25A2V1BW
FTXA35A2V1BW
FTXA42A2V1BW
FTXA50A2V1BW
CTXA15(A)(B)2V1BS
FTXA20(A)(B)2V1BS
FTXA25(A)(B)2V1BS
FTXA35(A)(B)2V1BS
FTXA42(A)(B)2V1BS
FTXA50(A)(B)2V1BS
CTXA15(A)(B)2V1BT
FTXA20(A)(B)2V1BT
FTXA25(A)(B)2V1BT
FTXA35(A)(B)2V1BT
FTXA42(A)(B)2V1BT
FTXA50(A)(B)2V1BT
CTXA15B2V1BB
FTXA20B2V1BB
FTXA25B2V1BB
FTXA35B2V1BB
FTXA42B2V1BB
FTXA50B2V1BB

Table of Contents

Other manuals for Daikin FTXA35A2V1BW

Questions and Answers

  • A
    April ParkerSep 9, 2025
    What to do if my Daikin FTXA35A2V1BW Air Conditioner user interface does NOT work well?
    • D
      Diana MillerSep 9, 2025
      If the operation switch on your Daikin Air Conditioner user interface does NOT work well, turn OFF the power supply.
  • R
    Raymond HodgeSep 7, 2025
    What to do if my Daikin FTXA35A2V1BW safety device actuates frequently?
    • S
      Shawn MartinezSep 8, 2025
      If a safety device such as a fuse, a breaker or an earth leakage breaker frequently actuates or the ON/OFF switch does NOT properly work, turn OFF the main power switch.
  • J
    juanblackAug 22, 2025
    What to do if my Daikin Air Conditioner system does NOT operate at all?
    • D
      Daniel WarrenAug 22, 2025
      If your Daikin Air Conditioner system isn't operating, check the following: * Ensure there is no power failure and wait for the power to be restored, as the system restarts automatically after a power outage. * Confirm the front panel is closed. If it's open, stop and restart the indoor unit using the user interface. * Check for blown fuses or activated breakers; replace the fuse or reset the breaker if needed. * Verify the batteries in the user interface are working. * Ensure the timer is properly set.
  • M
    Matthew SmithSep 5, 2025
    What to do if my Daikin Air Conditioner user interface display is blank?
    • D
      Darlene ParkerSep 5, 2025
      If the user interface display of your Daikin Air Conditioner is blank, replace the batteries in the user interface.
  • N
    Nicolas MartinSep 4, 2025
    What to do if my Daikin FTXA35A2V1BW Air Conditioner user interface display indicates a malfunction code?
    • J
      James Pham MDSep 4, 2025
      If the user interface displays the unit number, the operation lamp flashes, and a malfunction code appears, notify your installer and report the malfunction code.
  • L
    Lucas BaileySep 2, 2025
    Why does my Daikin FTXA35A2V1BW Air Conditioner ON/OFF timer does NOT operate according to the settings?
    • A
      Andrea BellSep 3, 2025
      If the ON/OFF timer isn't working as expected, check if the Weekly timer and ON/OFF timer are set to the same time. If they are, change or deactivate one of the settings. Also, verify that the clock and day of the week are set correctly.
  • J
    jfitzgeraldSep 1, 2025
    What to do if my Daikin FTXA35A2V1BW Air Conditioner heating operation CANNOT be selected?
    • J
      Julia BurchSep 1, 2025
      Check if the user interface's jumper J8 has NOT been cut.
  • J
    Jason ThompsonAug 31, 2025
    Why does my Daikin FTXA35A2V1BW Air Conditioner operation does NOT start soon?
    • J
      jenniferdeckerAug 31, 2025
      If the ON/OFF button was pressed right after operation was stopped or if the mode was changed, operation will start after 3 minutes to protect the system.
  • J
    jesusmcculloughAug 30, 2025
    What to do if my Daikin FTXA35A2V1BW Air Conditioner heating is insufficient and no air is blown from the unit?
    • B
      Brenda WongAug 30, 2025
      If heating is insufficient and no air is being blown from your Daikin Air Conditioner, it may be in warming up for heating operation. Wait for about 1 to 4 minutes. Alternatively, if you hear a flowing sound, the outdoor unit may be in defrost operation. In that case, wait for about 4 to 12 minutes.
  • B
    Brandon RamirezAug 28, 2025
    Why is my Daikin Air Conditioner not heating properly (no air is blown)?
    • S
      Sharon ThompsonAug 28, 2025
      If your Daikin Air Conditioner is running but not blowing hot air, it could be due to these reasons: * The air conditioner may be in the process of warming up for heating operation. Please wait for 1 to 4 minutes. * If you hear a flowing sound, the outdoor unit might be in defrost operation. Allow 4 to 12 minutes for this process to complete.

Summary

General Safety Precautions

Meaning of Warnings and Symbols

Explanation of safety symbols and their meanings used in the manual.

User Safety Guidelines

Instructions and warnings for the end-user's safe operation of the appliance.

Before Operation

Operation

Comfort and Intelligent Eye Features

Using comfort airflow and intelligent eye for enhanced operation.

Intelligent Eye Operation

Explanation of the intelligent eye sensor for energy saving.

Starting;Stopping Comfort and Intelligent Eye

How to activate or deactivate comfort and intelligent eye modes.

Powerful Operation

Instructions for maximizing cooling/heating effect quickly.

Energy Saving and Noise Reduction Modes

Using Econo and Outdoor Unit Quiet modes for efficiency.

Setting ON;OFF Timers

How to program the unit to turn on or off automatically.

Starting;Stopping OFF Timer

Procedure to set the timer for turning the unit off.

Starting;Stopping ON Timer

Procedure to set the timer for turning the unit on.

Programming Weekly Timers

Setting up multiple timers for different days of the week.

Wireless Connectivity Setup

Connecting the unit to a wireless network and smart devices.

Energy Saving and Optimal Performance

Maintenance and Servicing

Troubleshooting Common Issues

Diagnosing and Resolving Malfunctions

Guide to identifying and fixing common operating problems.

Resolving Error Code Issues

How to view and interpret error codes displayed on the unit.

Troubleshooting Wireless Connection Adapter

Solutions for problems related to wireless network connectivity.

Daikin FTXA35A2V1BW Specifications

General IconGeneral
TypeWall Mounted
Cooling Capacity3.5 kW
Heating Capacity4.0 kW
RefrigerantR-32
Energy Efficiency Class CoolingA++
Energy Efficiency Class HeatingA+
Outdoor Unit Weight32 kg
Seasonal Energy Efficiency Ratio (SEER)6.10
Power Supply230V/50Hz
Indoor Noise Level19 dB(A)
Energy Efficiency Ratio (Cooling)3.50
Energy Efficiency Ratio (Heating)4.00
Indoor Unit Noise Level (Low)19 dB(A)
Outdoor Unit Noise Level50 dB