EasyManua.ls Logo

Daikin FTXF-C - 10 Configuration; 10.1 Setting a Different Address

Daikin FTXF-C
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10 | Configuration
Installer reference guide
44
FTXF20~42C5V1B + ATXF20~42C5V1B
Daikin room air conditioner
4P519439-9J – 2021.06
10 Configuration
10.1 To set a different address
In case 2 indoor units are installed in 1 room, different addresses for 2 user
interfaces can be set.
1 Remove the batteries from the user interface.
2 Cut the address jumper.
a a
a Address jumper
NOTICE
Be careful NOT to damage any of the surrounding parts when cutting the address
jumper.
3 Turn the power supply on.
Result: The flap of the indoor unit will open and close to set the reference position.
INFORMATION
For FTXF and ATXF units, the following setting MUST be completed within
5minutes after the power supply is turned on.
In case you could NOT complete the setting in time, turn the power supply off
and wait at least 1minute before turning the power supply back on.
4 Press simultaneously:
Model Buttons
FTXF, ATXF
, and
5 Press:
Model Button
FTXF, ATXF
6 Select:
Model Symbol
FTXF, ATXF
7 Press:
Model Button
FTXF, ATXF

Table of Contents