Removal of Heat Exchanger Si04-858
38 Removal Procedure
4. Remove the heat
exchanger.
1
Slightly widen the
auxiliary piping.
2
Loosen the 2 screws on
the left.
3
Push the fixing hook on
the right side and lift the
heat exchanger.
Caution
When removing or
reinstalling heat exchanger,
be sure to wear protective
gloves or wrap the heat
exchanger with cloths. (Fins
can cut fingers.)
4
Pull the heat exchanger
to the front side and
then lift and remove it.
Step
Procedure Points
Auxiliary piping
(R19073)
(R3903)
Glove
(R3904)
(R3905)
Heat exchanger
(R3906)