Loading...
Outdoor Unit: 15/18/24 Class SiUS041111
218 Removal Procedure
4.8 Removal of Compressor
Procedure Warning Be sure to wait for 10 minutes or more after turning off all power supplies
before disassembling work.
Step Procedure Points
1 Remove the terminal
cover.
2 Disconnect the
compressor lead wires
and the overload
protector.
3 Remove the protection
bushing.
(R14343)
Terminal cover
(R14344)
(R14377)
Red (U)
Blue (W)
Yellow (V)
(R14345)
Protection bushing