Indoor Unit SiBE041102_A
108 Removal Procedure
2
Unfasten the hook, and
disconnect the
connector.
The connector of the swing
motor has a hook.
Press the hook with a flat
screwdriver to unfasten it.
3. Remove the display PCB.
1
Unfasten the hook, and
release the display PCB
ASSY.
2
Turn over the display
PCB ASSY, and
unfasten the 3 hooks to
remove the display
PCB.
Step Procedure Points
(R11651)
(R11652)
Display PCB ASSY
(R11653)
Hook
Display
PCB