Instruction SiENBE12-713
118 System Configuration
"
Outdoor Unit
"
Indoor Unit
"
Outdoor Unit
Appearance of the outdoor unit may differ from some models.
1. Air filter
2. Titanium Apatite Photocatalytic Air-
Purifying Filter:
• These filters are attached to the inside of
the air filters.
3. Air inlet
4. Front panel
5. Supporting plate:
• The supporting plate is used to support the
front panel during maintenance.
6. Panel tab
7. Flaps (horizontal blades)
8. Air outlet
9. Louvers (vertical blades):
• The louvers are inside of the air outlet.
10. Outlet vent panel
11. Display
12. Indoor Unit ON/OFF switch:
• Push this switch once to start operation.
Push once again to stop it.
• This switch is useful when the remote
control is missing.
• the operation mode refers to the following
table.
13. Room temperature sensor:
• it senses the air temperature around the
unit.
14. Operation lamp (green)
15. Timer lamp (Yellow)
16. INTELLIGENT EYE lamp (green)
17. INTELLIGENT EYE sensor:
• It detects the movements of people and
automatically switches between normal
operation and energy saving operation.
18. Signal receiver
• It receives signals from the remote control.
• When the unit receives a signal, you will hear
a short beep.
• Operation start ..............beep-beep
• Settings changed .............beep
• Operation stop ...............beeeeep
19. Air inlet:
(Back and side)
20. Air outlet
21. Refrigirant piping and inter-unit cable
22. Drain hose
23. Earth terminal:
• It is inside of this cover.
Mode Temperature
setting
Air flow
rate
F(C)TXG AUTO 25°C AUTO