EasyManua.ls Logo

Daikin FTXS20LVMA - Advanced Operation Modes; Powerful Operation Guide

Daikin FTXS20LVMA
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Removal of PCBs (Pattern 1) Si041137
16 Removal Procedure
3
Remove the signal
receiver unit.
4. Remove the
INTELLIGENT EYE
sensor PCB.
1
Unfasten the 3 hooks
and remove the
INTELLIGENT EYE
sensor PCB.
2
Disconnect the
connector [S26] from
the INTELLIGENT EYE
sensor PCB.
Step
Procedure Points
(R12278)
Hook
(R8088)
Signal receiver unit
(R8092)
INTELLIGENT EYE
sensor PCB
(R8093)
[S26]

Other manuals for Daikin FTXS20LVMA

Related product manuals