Wiring Diagrams EDUS041129
10 Split Type Air Conditioners FTXS-L Series
5. Wiring Diagrams
FTXS30/36LVJU
RKS30/36LVJU, RXS30/36LVJU
1
X1M
PCB1PCB3
S46S49
2
H1
BLK
11
BLK
1
3
BLK
3.15A
WHT
~
OUTDOOR
2
BLK
C102 V1
BLK
RED
3
H2
MR10
BLK
GRN
BLK
FIELD WIRING.
BLK
C101
BLK
H3
99
BLK
CAUTION
FG
SW1
S21
S1
HA
7
RED
BZ
4
BLU
S25
BLK
MS
3~
BRN
1
1
PCB4
BLK
ORG
S36
1
WHT
3
S41S47 S32
BLK
4
M1F
12
1
16 14 11
1
73
1
81552213910 643
BLK
BLK
BLK
BLK
BLK
PNK
PNK
PNK
BLU
BLU
BLU
RED
RED
RED
ORG
ORG
ORG
YLW
YLW
YLW
S48PCB2
1
3
INDOOR
R2T
MSW MSWMSW
M1S M3SM2S
GRN
/
YLW
SIGNAL
RECEIVER
WIRELESS
REMOTE
CONTROLLER
INTELLIGENT EYE
SENSOR
RTH1
R1T
LED3
H3P
LED2
H2P
LED1
H1P
TRANSMISSION
CIRCUIT
FU1
F1U
NOTE THAT OPERATION WILL RESTART
AUTOMATICALLY IF THE MAIN POWER SUPPLY
IS TURNED OFF AND THEN BACK ON AGAIN.
BZ
C101, C102
FG
F1U
H1P~H3P
MR10
M1F
M1S~M3S
PCB1~PCB4
R1T
,
R2T
S1~S49
SW1
V1
X1M
: BUZZER
: CAPACITOR
: FRAME GROUND
: FUSE
: PILOT LAMP
: MAGNETIC RELAY
: FAN MOTOR
: SWING MOTOR
: PRINTED CIRCUIT BOARD
: THERMISTOR
: CONNECTOR
: OPERATION SWITCH
: VARISTOR
: TERMINAL STRIP
: PROTECTIVE GROUND
C: 3D060942H
S80
IN CASE OF
COOLING
ONLY TYPE
41
L1R
GRN
Z6C
GRN
N=1
YLW
N=1
Z1C
X1M
Z8C
FU3
GRN
7
BLU
WHT
RED
M1F
E1
N=4
E2
L1
HR2
SA2
HR1
MRM20
3.15A
POWER SUPPLY
V100
N=4
FU1
MS
V2
Z2C
AC1
BLU
MRM10
30A
L
1
3 ~
L2
BRN
6(P)
1
BRN
L
2
S70
+++
9
8
ORG
1
WHT
V9
7(N)
AC2
Z3C
N=3
2
N=3
BLU
TO INDOOR UNIT
BLK
M1C
Z5C
PM1
X11A
N=3
U
WHT
U
GR
X2M
GR
Z4C
RED
5
RED
1
1
1
V
V
MS
RED
YLW
4
YLW
2
FU2
3.15A
2
3 ~
S10
W
W
3
BLU
3
BLU
3
MR30
V3
Q1L
BLK
BLK
PCB1
S40
MRC/W
41
V5
SHEET METAL
S90
S51 S101 S80 S20
541115
6
1
61
INDOOR
Z7C
N=1
RED
BLK
BLK
BLU
BLU
BLU
BLU
BLU
BLK
GRY
RED
RED
GRN
WHT
FIELD WIRING
ORG
BLK
RED
GRY
YLW
151
S102
5
S52
R1T
R2T
R3T
PCB2
M
Y1S
S2
(OUTDOOR)
(DISCHARGE)
LED A
Y1E
(CONDENSER)
SW4SW1
OUTDOOR
Z1C~Z8C
X1M, X2M
Y1E
V2, V3, V5, V9, V100
SA2
FU1, FU2, FU3
AC1, AC2
U, V, W, X11A
E1, E2
HR1, HR2
: FERRITE CORE
: TERMINAL STRIP
:
ELECTRONIC EXPANSION VALVE COIL
: VARISTOR
: SURGE ABSORBER
: FUSE
: CONNECTOR
MRM10, MRM20
MRC/W, MR30
R1T~R3T
S2~S102
LED A
: MAGNETIC RELAY
: THERMISTOR
: CONNECTOR
: PILOT LAMP
L
1, L2
SW1
SW4
: LIVE
:
FORCED COOLING OPERATION SWITCH (SW1)
: LOCAL SETTING SW (SW4)
M1C
M1F
L1R
Q1L
PM1
PCB1, 2
Y1S
SHEET METAL
GR
: COMPRESSOR MOTOR
: FAN MOTOR
: REACTOR
: OVERLOAD PROTECTOR
: POWER MODULE
: PRINTED CIRCUIT BOARD
: REVERSING SOLENOID VALVE COIL
: TERMINAL STRIP FIXED PLATE
: PROTECTIVE GROUND
: GROUND
3D074291A