EDUS041129 Capacity Tables
Split Type Air Conditioners FTXS-L Series 15
7.2 Heat Pump
FTXS30LVJU + RXS30LVJU (60 Hz, 208 - 230 V)
Cooling
Heating
AFR 20.0
BF 0.23
Temp: Celsius
TC, SHC, PI: kW
INDOOR OUTDOOR TEMPERATURE (°CDB)
EWB EDB 20 25 30 32 35 40
°C °C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
14.0 20.0 6.92 4.97 1.38 6.92 4.97 1.61 6.92 4.97 1.88 6.92 4.97 2.00 6.92 4.97 2.20 6.92 4.97 2.46
16.0 22.0 8.63 5.59 1.85 8.63 5.59 2.18 8.60 5.58 2.57 8.44 5.49 2.66 8.19 5.37 2.78 7.78 5.16 2.81
18.0 25.0 9.83 6.19 2.17 9.42 5.99 2.38 9.01 5.78 2.59 8.84 5.70 2.67 8.60 5.59 2.79 8.19 5.39 2.82
19.4 26.7 10.03 6.43 2.18 9.62 6.23 2.39 9.21 6.04 2.59 9.05 5.96 2.68
8.80 5.84 2.80 8.39 5.66 2.83
22.030.010.646.172.2010.235.992.409.825.822.619.655.752.699.415.652.829.005.482.84
24.0 32.0 11.04 5.97 2.21 10.63 5.81 2.42 10.22 5.65 2.62 10.06 5.59 2.71 9.81 5.49 2.83 9.40 5.34 2.86
Temp: Fahrenheit
TC, SHC: kBtu/h
PI: kW
INDOOR OUTDOOR TEMPERATURE (°FDB)
EWB EDB 68 77 86 90 95 104
°F °F TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
57.2 68.0 23.61 16.97 1.38 23.61 16.97 1.61 23.61 16.97 1.88 23.61 16.97 2.00 23.61 16.97 2.20 23.61 16.97 2.46
60.8 71.6 29.44 19.09 1.85 29.44 19.09 2.18 29.35 19.04 2.57 28.79 18.75 2.66 27.95 18.31 2.78 26.55 17.61 2.81
64.4 77.0 33.53 21.13 2.17 32.13 20.43 2.38 30.73 19.74 2.59 30.17 19.47 2.67 29.33 19.06 2.79 27.94 18.40 2.82
67.0 80.0 34.22 21.94 2.18 32.82 21.26 2.39 31.42 20.59 2.59 30.86 20.33 2.68
30.00 19.94 2.80 28.63 19.30 2.83
71.6 86.0 36.29 21.04 2.20 34.90 20.43 2.40 33.50 19.84 2.61 32.94 19.61 2.69 32.10 19.26 2.82 30.70 18.69 2.84
75.2 89.6 37.68 20.37 2.21 36.28 19.82 2.42 34.88 19.28 2.62 34.32 19.06 2.71 33.48 18.74 2.83 32.09 18.22 2.86
AFR 20.1
Temp: Celsius
TC, PI: kW
INDOOR OUTDOOR TEMPERATURE (°CWB)
EDB –15 –10 –5 0 6 10
°C TC PI TC PI TC PI TC PI TC PI TC PI
15.0 4.86 2.51 6.17 2.68 6.82 2.77 9.17 3.62 10.55 3.81 11.47 3.94
21.1 4.56 2.58 5.87 2.75 6.52 2.84 8.82 3.71
10.20 3.90 10.69 3.70
22.0 4.44 2.61 5.75 2.78 6.40 2.87 8.68 3.74 10.01 3.89 10.01 3.34
24.0 4.32 2.64 5.63 2.81 6.28 2.89 8.54 3.78 9.33 3.49 9.33 3.01
25.0 4.26 2.65 5.57 2.82 6.22 2.91 8.47 3.80 8.99 3.30 8.99 2.86
27.0 4.14 2.68 5.45 2.85 6.10 2.94 8.31 3.82 8.31 2.94 8.31 2.56
Temp: Fahrenheit
TC: kBtu/h
PI: kW
INDOOR OUTDOOR TEMPERATURE (°FWB)
EDB 5 14 23 32 43 50
°F TC PI TC PI TC PI TC PI TC PI TC PI
59.0 16.57 2.51 21.05 2.68 23.25 2.77 31.29 3.62 36.00 3.81 39.15 3.94
70.0 15.55 2.58 20.03 2.75 22.23 2.84 30.09 3.71
34.80 3.90 36.46 3.70
71.6 15.14 2.61 19.62 2.78 21.82 2.87 29.61 3.74 34.15 3.89 34.15 3.34
75.2 14.74 2.64 19.21 2.81 21.42 2.89 29.13 3.78 31.83 3.49 31.83 3.01
77.0 14.53 2.65 19.01 2.82 21.21 2.91 28.89 3.80 30.67 3.30 30.67 2.86
80.6 14.12 2.68 18.60 2.85 20.80 2.94 28.36 3.82 28.36 2.94 28.36 2.56