Capacity Tables EDUS041129
18 Split Type Air Conditioners FTXS-L Series
<60 Hz, 230 V>
Cooling
Heating
AFR 21.8
BF 0.27
Temp: Celsius
TC, SHC, PI: kW
INDOOR OUTDOOR TEMPERATURE (°CDB)
EWB EDB 20 25 30 32 35 40
°C °C TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
14.0 20.0 7.15 5.14 1.54 7.15 5.14 1.77 7.15 5.14 2.05 7.15 5.14 2.17 7.15 5.14 2.38 7.15 5.14 2.67
16.0 22.0 8.92 5.78 2.09 8.92 5.78 2.44 8.92 5.78 2.87 8.92 5.78 3.07 8.92 5.78 3.41 8.92 5.78 3.89
18.0 25.0 10.82 6.74 2.80 10.82 6.74 3.35 10.75 6.70 3.97 10.55 6.60 4.10 10.26 6.45 4.29 9.60 6.12 4.24
19.4 26.7 11.82 7.38 3.25 11.48 7.20 3.66 10.99 6.95 3.98 10.79 6.86 4.11
10.50 6.71 4.30 9.82 6.38 4.24
22.0 30.0 12.69 7.14 3.37 12.20 6.91 3.69 11.71 6.69 4.01 11.52 6.60 4.14 11.23 6.47 4.33 10.50 6.16 4.24
24.0 32.0 13.18 6.90 3.39 12.69 6.69 3.71 12.20 6.49 4.03 12.00 6.41 4.16 11.71 6.29 4.35 10.95 5.99 4.24
Temp: Fahrenheit
TC, SHC: kBtu/h
PI: kW
INDOOR OUTDOOR TEMPERATURE (°FDB)
EWB EDB 68 77 86 90 95 104
°F °F TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI
57.2 68.0 24.39 17.54 1.54 24.39 17.54 1.77 24.39 17.54 2.05 24.39 17.54 2.17 24.39 17.54 2.38 24.39 17.54 2.67
60.8 71.6 30.43 19.72 2.09 30.43 19.72 2.44 30.43 19.72 2.87 30.43 19.72 3.07 30.43 19.72 3.41 30.43 19.72 3.89
64.4 77.0 36.91 23.00 2.80 36.91 23.00 3.35 36.67 22.87 3.97 36.00 22.52 4.10 35.00 22.01 4.29 32.75 20.89 4.24
67.0 80.0 40.33 25.18 3.25 39.16 24.57 3.66 37.49 23.72 3.98 36.83 23.39 4.11
36.00 22.89 4.30 33.52 21.78 4.24
71.6 86.0 43.31 24.36 3.37 41.64 23.58 3.69 39.97 22.83 4.01 39.30 22.53 4.14 38.30 22.09 4.33 35.82 21.01 4.24
75.2 89.6 44.96 23.54 3.39 43.29 22.83 3.71 41.62 22.14 4.03 40.95 21.86 4.16 39.95 21.46 4.35 37.35 20.43 4.24
AFR 22.9
Temp: Celsius
TC, PI: kW
INDOOR OUTDOOR TEMPERATURE (°CWB)
EDB –15 –10 –5 0 6 10
°C TC PI TC PI TC PI TC PI TC PI TC PI
15.0 5.29 2.70 6.35 2.84 7.42 2.98 9.98 3.90 11.48 4.11 12.49 4.24
21.1 4.96 2.78 6.03 2.92 7.09 3.06 9.60 3.99
11.10 4.20 12.10 4.34
22.0 4.83 2.81 5.90 2.95 6.96 3.09 9.44 4.03 10.95 4.24 11.95 4.38
24.0 4.70 2.84 5.77 2.98 6.83 3.12 9.29 4.07 10.79 4.28 11.39 4.08
25.0 4.63 2.85 5.70 2.99 6.77 3.13 9.21 4.09 10.72 4.29 10.97 3.83
27.0 4.50 2.88 5.57 3.02 6.64 3.16 9.06 4.12 10.15 3.96 10.15 3.37
Temp: Fahrenheit
TC: kBtu/h
PI: kW
INDOOR OUTDOOR TEMPERATURE (°FWB)
EDB 5 14 23 32 43 50
°F TC PI TC PI TC PI TC PI TC PI TC PI
59.0 18.04 2.70 21.67 2.84 25.31 2.98 34.05 3.90 39.18 4.11 42.60 4.24
70.0 16.92 2.78 20.56 2.92 24.20 3.06 32.74 3.99
38.00 4.20 41.29 4.34
71.6 16.48 2.81 20.12 2.95 23.75 3.09 32.22 4.03 37.35 4.24 40.77 4.38
75.2 16.04 2.84 19.67 2.98 23.31 3.12 31.70 4.07 36.83 4.28 38.86 4.08
77.0 15.81 2.85 19.45 2.99 23.08 3.13 31.43 4.09 36.57 4.29 37.44 3.83
80.6 15.37 2.88 19.00 3.02 22.64 3.16 30.91 4.12 34.62 3.96 34.62 3.37