Indoor Unit: FTXS15/18/24LVJU SiUS091133
205 Removal Procedure
2.5 Removal of Horizontal Blades / Swing Motors
Procedure Warning Be sure to wait for 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure Points
1. Remove the horizontal
blades.
1
Hold the indoor unit up
with something sturdy
such as a piece of
wood.
2
Release the shafts in
turn.
(R9568)
Horizontal blade
(R9536)
left
(R9537)
inner right

Table of Contents