EasyManua.ls Logo

Daikin FTXS30LVJU - Removal of Horizontal Blades; Swing Motors

Daikin FTXS30LVJU
414 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Indoor Unit: FTXS30/36LVJU SiUS091133
241 Removal Procedure
3.5 Removal of Horizontal Blades / Swing Motors
Procedure Warning Be sure to wait for 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure Points
1. Remove the horizontal
blades.
1
Hold the indoor unit up
with a piece of wood
etc.
2
Remove the screw at
the rear of the indoor
unit.
3
Remove the 2 screws
(front and rear).
(R9568)
Horizontal blade
(R9533)
(R9534)

Table of Contents

Other manuals for Daikin FTXS30LVJU

Related product manuals