Loading...
Si041259EA PCBs
Removal Procedure 9
2. Remove the
INTELLIGENT EYE
sensor PCB.
1
Unfasten the 2 hooks
and remove the shield
plate.
2
Unfasten the 3 hooks
and remove the
INTELLIGENT EYE
sensor PCB.
[S26]: control PCB
3
Disconnect the
connector [S26].
3. Remove the display PCB.
1
Turn over the signal
receiver unit.
2
Unfasten the 4 hooks
and remove the display
PCB.
3
Disconnect the
connector [S49]. [S49]: control PCB
Step
Procedure Points
(R19040)
Shield plate
Hook
Hook
Hook
INTELLIGENT
EYE sensor
PCB
[S26]
(R19041)
Display PCB
(R19042)
Hook
Hook
(
R19043
)
[S49]