EasyManua.ls Logo

Daikin FTXS50K2V1B - Controlling Airflow Direction; Auto Swing and 3 D Airflow; Manual Flap and Louver Adjustment

Daikin FTXS50K2V1B
23 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Swing Motors Si041259EA
12 Removal Procedure
4
Disconnect the
connector (green) from
the swing motor.
5
Remove the 2 screws
and remove the swing
motor for horizontal
blade (large).
6
Disconnect the
connector (red) from
the swing motor.
When reassembling, mount
the swing motor for
horizontal blade (large) first.
(connector: red)
Next, mount the swing motor
for horizontal blade (small).
(connector: green)
7
Release the swing
motor harness from the
hook of the cover link
(1).
Step
Procedure Points
(R19048)
(R19049)
Swing motor
for horizontal
blade (large)
(R19050)
(R19051)
Cover link (1)
Hook