Si041259EA Swing Motors
Removal Procedure 13
2. Remove the swing motor
for vertical blade ASSY.
Place a plastic sheet under
the drain pan to prevent from
wetting the floor with
remaining drain.
If the drain hose is
embedded in the wall,
disconnect the drain hose
beforehand.
Carry out the removal work
with 2 wrenches.
When the pipings are
disconnected, protect both
the openings of pipe and unit
from entering moisture.
1
Remove the 2 screws
which fix the indoor unit
to the installation plate.
2
Disconnect the gas
piping and the liquid
piping.
3
Detach the indoor unit
from the installation
plate.
4
Unfasten the hook and
remove the piping
fixture on the back of
the indoor unit.
5
Slightly widen the
auxiliary piping.
Step
Procedure Points
(R19059)
(R19060)
(R19052)
Piping fixture
(R19053)
Auxiliary piping