EasyManua.ls Logo

Daikin FVXS35BVMA - User Manual

Daikin FVXS35BVMA
298 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
C-Series
[Applied Models]
zInverter Multi : Cooling Only
zInverter Multi : Heat Pump
Si12 - 411A

Table of Contents

Questions and Answers

Summary

Introduction

1.1 Safety Cautions

Crucial safety guidelines to prevent injury or damage.

1.1.1 Caution in Repair

Specific warnings and precautions during repair work.

Part 1 List of Functions

Part 2 Specifications

1.1 Indoor Units - Cooling Only

Technical specifications for cooling-only indoor units.

1.2 Outdoor Units - Cooling Only

Technical specifications for cooling-only outdoor units.

1.3 Indoor Units - Heat Pump

Technical specifications for heat pump indoor units.

1.4 Outdoor Units - Heat Pump

Technical specifications for heat pump outdoor units.

Part 3 Printed Circuit Board Connector Wiring Diagram

1.1 Wall Mounted Type 20;25;35 Class

Wiring diagram for specific wall-mounted indoor units.

1.6 Outdoor Units

Wiring diagram for outdoor units.

Part 4 Function and Control

Part 5 System Configuration

2.2 Safety Precautions

Essential safety guidelines for installation and operation.

Part 6 Service Diagnosis

1.1 Troubleshooting with the Operation Lamp

Using the operation lamp status for basic troubleshooting.

2. Problem Symptoms and Measures

Common issues and their corresponding solutions.

6. Check

Part 7 Removal Procedure

Summary

Introduction

1.1 Safety Cautions

Crucial safety guidelines to prevent injury or damage.

1.1.1 Caution in Repair

Specific warnings and precautions during repair work.

Part 1 List of Functions

Part 2 Specifications

1.1 Indoor Units - Cooling Only

Technical specifications for cooling-only indoor units.

1.2 Outdoor Units - Cooling Only

Technical specifications for cooling-only outdoor units.

1.3 Indoor Units - Heat Pump

Technical specifications for heat pump indoor units.

1.4 Outdoor Units - Heat Pump

Technical specifications for heat pump outdoor units.

Part 3 Printed Circuit Board Connector Wiring Diagram

1.1 Wall Mounted Type 20;25;35 Class

Wiring diagram for specific wall-mounted indoor units.

1.6 Outdoor Units

Wiring diagram for outdoor units.

Part 4 Function and Control

Part 5 System Configuration

2.2 Safety Precautions

Essential safety guidelines for installation and operation.

Part 6 Service Diagnosis

1.1 Troubleshooting with the Operation Lamp

Using the operation lamp status for basic troubleshooting.

2. Problem Symptoms and Measures

Common issues and their corresponding solutions.

6. Check

Part 7 Removal Procedure

Daikin FVXS35BVMA Specifications

General IconGeneral
Cooling Capacity3.5 kW
Heating Capacity4.0 kW
Power Supply220-240 V, 50 Hz
RefrigerantR32
Seasonal Energy Efficiency Ratio (SEER)6.1
Outdoor Unit Dimensions (HxWxD)550 x 780 x 285 mm

Related product manuals