Installation Manual EDUS391777-F17
15 FXSQ-TAVJU
3P184443-13Z
15
English
WARNING
r When wiring, form the wirings orderly so that the control
DQZNKFECPDGUGEWTGN[HCUVGPGF+HVJGEQPVTQNDQZNKFKUPQV
in place, the wirings may come out or be sandwiched by the
DQZCPFVJGNKFCPFECWUGGNGEVTKEUJQEMUQTCƂTG
(1) Remove the control box lid.
Screws
(2 points)
Fig. 23
(2)
Attach the conduit to the conduit mounting plate (12).
Conduit mounting
plate (12)
Conduit
ƂGNFUWRRN[
Lock nut
ƂGNFUWRRN[
Fig. 24-1
r Attach the wire sealing material (small) (10) to the con-
duit, the power supply wiring and the ground wiring.
Conduit mounting
plate (12)
Conduit
mounting
plate (12)
Conduit
ƂNGFUWRRN[
9KTGUGCNKPIOCVGTKCNUOCNN
2QYGTUWRRN[
wiring and ground
wiring
8KGYGFHTQOVJGUKFG
Fig. 24-2
r Loosen the screws (2 points) in part A.
Screws
(2 points)
B
A
9KTKPIƂZVWTG
Fig. 24-3
r Insert the hook part of the conduit mounting plate (12)
into part B and secure the conduit mounting plate (12)
with the screws loosened (2 points).
NOTE
1. 4GOQXGVJGYKTKPIƂZVWTGKH[QWJCXGFKH ƂEWNV[KP
performing this step.
Screws
(2 points)
Conduit mounting
plate (12)
Hook
Fig. 24-4
(3)
Connect the wiring into the control box through the
wiring intake beside the control box.
Remote controller
wiring
Transmission
wiring
Wiring intake
(low voltage)
Wiring intake
(high voltage)
Power supply
wiring and
ground wiring
Fig. 25
(4) Follow the instructions below and perform wiring in
the control box.
F2
T2
P1
P2
F1 T1
5GEWTGN[ƂZVJGYKTKPIVQ
VJGRTQXKFGFYKTKPIƂZVWTG
YKVJVJGENCOR
6GTOKPCNDNQEM:/
HQTRQYGTUWRRN[YKTKPI
CPFITQWPFYKTKPI
%QPPGEVVJGYKTKPI
VJTQWIJVJGEQPVTQNDQZ
WRVQVJGUJGCVJGFRCTV
2QYGTUWRRN[YKTKPI
JKIJXQNVCIG
)TQWPFYKTKPIJKIJXQNVCIG
4GOQVGEQPVTQNNGTYKTKPI
NQYXQNVCIG
6GTOKPCNDNQEM:/HQTTGOQVGEQPVTQNNGTYKTKPI
CPFVTCPUOKUUKQPYKTKPI
4GOQVGEQPVTQNNGTYKTKPI
0QRQNCTKV[
6TCPUOKUUKQPYKTKPI
0QRQNCTKV[
4GOQVGEQPVTQNNGTYKTKPIOGVJQF
Never connect the
power supply wiring.
Prohibited
%QPPGEVKQPOGVJQF
HQTRQYGTUWRRN[YKTKPI
CPFITQWPFYKTKPI
:1/
L1
L2
Fig. 26
NOTE
1. Secure the wiring between the wiring intake and conduit
with the clamp (8) so that the wiring will not become loose.