2-6
1 Set Point temperature Change
1. Press key to change Set Point temperature. Press key to determine.
Set Temp. Range : -30.0 to +30.0 .
2 Mode Set
2-1 Defrost Interval Set
2-2 Humidity Set
When Reheat Coil is set to "OFF" in 12
Configuration Set, this function will not work.
2-3 Humidity Set
2-4 USDA Set
2-5 Automatic set point change
When ASC function is set to "OFF" in 13 Optional
Function, this function will not work.
2-6 Automatic Cold Treatment Set (Option)
When ACT function is set to "OFF" in 13 Optional
Function and USDA is "OFF" in 2-4 USDA
setting, this function will not work.
2-7 G-SET Set
2-8 Fan Speed Control
2-1 Defrost Interval Set
1. Press
key to select defrost interval and press key to determine.
Time setting: 3, 6, 9, 12, 24 Hr
Auto setting: AUTO (Defrosting will executed automatically in accordance with the state of frost
formation occurred on the evaporator coil.)
2-2 Dehumidification Operation Set
1. Press key to select "ON", "ON-A", "Bulb" or "OFF" and press key to determine.
ON: Dehumidification operation is conducted. (For unit equipped with humidity sensor)
ON-A : Dehumidification operation is conducted. (For unit not equipped with humidity sensor)
Bulb: When dehumidifying (the Bulb mode is set to "ON" in 13 Optional Function)
OFF: When dehumidification operation is not conducted
Note: ON-A and Bulb are optional functions.
Mode Set
Humidity Set
Humidity Setpoint
USDA
OFF
65%RH
OFF
Auto Setpoint Change
Auto Cold Treatment
G-SET
Defrost Interval
9Hrs
OFF
OFF
OFF
Fan Speed Control
OFF
Defrost Interval
▲▼ : Change
ENTER : Confirm
12 Hour
Defrost Interval
▲▼ : Change
ENTER : Confirm
9 Hour