DAIKIN CONTAINER
LXE10E-A14
LXE10E-A15
TR 02-14
Marine type
Container Refrigeration Unit
Service Manual
Head Office. Umeda Center Bldg., 4-12, Nakazaki-Nishi 2-chome, Kita-ku, Osaka, 530-8323 Japan.
Tel: 06-6373-4338
Fax: 06-6373-7297
Tokyo Office. JR Shinagawa East Bldg., 10F 18-1, Konan 2-chome, Minato-ku Tokyo, 108-0075 Japan.
Tel: 03-6716-0420
Fax: 03-6716-0230
Marine type Container Refrigeration Unit Service Manual LXE10E-A14
LXE10E-A15
https://daikin-p.ru

Table of Contents

Questions and Answers

  • C
    Carol EverettJul 25, 2025
    Why my Daikin LXE10E-A15 Heat Pump unit does not operate?
    • U
      uparsonsJul 25, 2025
      If your Daikin Heat Pump isn't operating, several factors could be at play. First, check for a power failure and restore power if necessary. Ensure the equipment power supply is turned on and that the power plug is correctly connected and making good contact. Also, verify that the circuit breaker is activated. In addition, the unit might have shut down due to an alarm; resolve the alarm condition and reset the unit.
  • S
    Scott MaxwellAug 13, 2025
    How to fix a Daikin LXE10E-A15 Heat Pump compressor that buzzes but does not operate?
    • V
      victoria78Aug 13, 2025
      If the compressor in your Daikin Heat Pump buzzes but doesn't start, it could be due to a few potential issues. Check for an open phase and restore it. The compressor may also be locked, in which case you should unlock it. Low supply voltage could also be the cause, so ensure that the voltage supply is adequate. Lastly, the motor coil might be burned out or short-circuited, requiring replacement.
  • G
    garrettodonnellNov 3, 2025
    What to do if my Daikin Heat Pump operates but soon stops?
    • C
      Christina PadillaNov 4, 2025
      If your Daikin Heat Pump operates briefly and then stops, it could be due to several reasons: * A malfunctioning high-pressure switch (replace it). * Closed liquid solenoid or electronic expansion valves (open the solenoid valve). * Overcurrent from overload (reduce the load on the unit). * Refrigerant overcharge (reduce the refrigerant charge). * Air in the refrigerant system (eliminate the air). * Insufficient airflow in the air-cooled condenser (ensure adequate airflow). * Blocked condenser coil (clean the fins). * Blocked air passage (remove any foreign material). * A broken condenser fan blade (replace it). * Condenser fan motor failure (repair or replace the motor). * Activation of the condenser fan motor's thermal protector (allow it to cool and check for over...

Summary

Safety Precautions

Danger

Critical warnings about immediate hazards and potential severe injury or death.

Warning

Important safety instructions to prevent potential hazards that could cause injury or death.

Caution

Instructions to prevent potential hazards that could cause minor injury or equipment damage.

3. Electronic Controller

3.4 Alarm Display and Back-up Function

Lists alarm codes and explains backup operations during sensor malfunctions.

4. Service and Maintenance

4.1 Main Components and Maintenance

Covers maintenance procedures for key components like the compressor.

4.4 Maintenance Service

Covers essential maintenance tasks such as refrigerant collection and gauge manifold use.

6. Troubleshooting

6.1 Refrigeration System and Electrical System

Provides a table of malfunctions, abnormal points, and possible causes.

6.2 Alarm Codes on Electronic Controller

Lists and explains alarm codes generated by the electronic controller.

6.3 Troubleshooting for Automatic PTI (J-code)

Offers troubleshooting steps based on J-codes for automatic PTI.

6.5 Emergency Operation

Outlines procedures for emergency operation of the unit.

Daikin LXE10E-A15 Specifications

General IconGeneral
BrandDaikin
ModelLXE10E-A15
CategoryHeat Pump
LanguageEnglish