OM 1280-2 • MICROTECH UNIT CONTROLLER 72 www.DaikinApplied.com
Menu Name
(Menu Index)
Minimum Password to Read
(None, User, Manager, Technician)
Minimum Password to Write
(None, User, Manager, Technician)
“RO” if Read Only
Help Text
CfgBO1: T T Binary output 1 virtual function select.
CfgBO2: T T Binary output 2 virtual function select.
CfgBO3: T T Binary output 3 virtual function select.
CfgBO4: T T Binary output 4 virtual function select.
CfgBO5: T T Binary output 5 virtual function select.
CfgBO6: T T Binary output 6 virtual function select.
CfgBO7: T T Binary output 7 virtual function select.
CfgBO8: T T Binary output 8 virtual function select.
CfgBO9: T T Binary output 9 virtual function select.
CfgBO10: T T Binary output 10 virtual function select.
CfgBO11: T T Binary output 11 virtual function select.
CfgBO12: T T Binary output 12 virtual function select.
CfgBO13: T T Binary output 13 virtual function select.
CfgBO14: T T Binary output 14 virtual function select.
CfgRevVlv_Rev: T T Reversing valve output reverse acting.
CfgHtEOC_Rev: T T Hot water EOC output reverse acting.
CfgClEOC_Rev: T T Cold water EOC output reverse acting.
CfgDrPnHt_Rev: T T Drain pan heater output reverse acting.
CfgFltOut_Rev: T T Binary output 5 reverse acting.
CfgDmpEndRev: T T Damper end input reverse acting.
Serv|BinOut|Virtual
FanLow: T RO Fan low status.
FanMed: T RO Fan medium status.
FanHigh: T RO Fan high status.
RevVlv: T RO Reversing valve status.
FltOut: T RO Fault alarm status.
OutFan: T RO Outside fan status.
ExhFan: T RO Exhaust fan status.
Pump: T RO Pump status.
ElHt1: T RO Electric heat 1 status.
ElHt2: T RO Electric heat 2 status.
ElHt3: T RO Electric heat 3 status.
CmpStg1: T RO Compressor stage 1 status.
CmpStg2: T RO Compressor stage 2 status.
DrnPanHtr: T RO Drain pan heater status.
HotWtrEOC: T RO Hot water end of cycle valve status.
ColdWtrEOC: T RO Cold water end of cycle valve status.
ECMEn: T RO ECM enable status.
Serv|BinOut|Overide
ShutdownOR: T T
OrLED: T T Binary output LED override.
OrFanLow: T T Low fan output override.
OrFanMed: T T Medium fan output override.
OrFanHi: T T High fan output override.
OrRevVlv: T T Reversing valve output override.
OrFaultOut: T T Fault output override.
OrOutFan: T T Outside fan output override.
OrExhFan: T T Exhaust output override.
OrPump: T T Pump output override.
OrElectHt1: T T Electric heat 1 output override.
OrElectHt2: T T Electric heat 2 output override.
OrElectHt3: T T Electric heat 3 output override.
OrComp1: T T Compressor 1 output override.
OrComp2: T T Compressor 2 output override.
OrDrnPanHt: T T Drain pan heater output override.
OrHtWtrEOC: T T Hot water EOC valve output override.
OrClWtrEOC: T T Cold water EOC valve output override.
OrEcmEn: T T ECM enable output override.
OrAuxHt: T T Aux heat output override.
Serv|PWM
Serv|PWM|Status
pwmECMSuppFan: T RO ECM supply fan output.
Serv|PWM|Override
OrECMSuppFan: T T ECM supply fan override.
BMSComm|BACnet
BMSComm
NetInAlarm: N RO LonWorks unit status InAlarm.
NetMode: N RO LonWorks unit status Mode.
NetHtPri: N RO LonWorks unit status Heat Out Primary.
NetHtSec: N RO LonWorks unit status Heat Out Secondary.
NetCool: N RO LonWorks unit status Cool Out.