Rooftop Equipment Warranty Registration Form (continued)
13F-4158 (06/17) 3
Select Yes or No. If not applicable to the type of unit, select N/A.
III. START-UP COMPRESSOR OPERATION
A. Do compressors have holding charges?
Circuit #1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Yes No N/A
Circuit #2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Yes No N/A
B. Are compressors rotating in the right direction? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ye s No N/A
C. Do condenser fans rotate in the right direction? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Yes No N/A
D. Ambient temperature (°F): . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . _____________
E. Does unit start up and perform per sequence of operation?. . . . . . . . . . . . . . . . . . . . . . . . . . Ye s No N/A
IV. PERFORMANCE DATA
A. Compressor voltage across each phase: . . . . . . . . . 1–2_____________ V 2–3 _____________ V 1–3 _____________ V
B. Compressor amperage of fully loaded compressor: Compressor #1 — Phase 1________ Phase 2 ________ Phase 3 _______
Compressor #2 — Phase 1________ Phase 2 ________ Phase 3 _______
Compressor #3 — Phase 1________ Phase 2 ________ Phase 3 _______
Compressor #4 — Phase 1________ Phase 2 ________ Phase 3 _______
Compressor #5 — Phase 1________ Phase 2 ________ Phase 3 _______
Compressor #6 — Phase 1________ Phase 2 ________ Phase 3 _______
C. Low pressure cut-out: . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Circuit 1 __________ psig Circuit 2 __________ psig
D. Low pressure cut-in: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Circuit 1 __________ psig Circuit 2 __________ psig
E. High pressure cut-out: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Circuit 1 __________ psig Circuit 2 __________ psig
F. Discharge pressure, one compressor: . . . . . . . . . . . . . . . . . . . . . Circuit 1 __________ psig Circuit 2 __________ psig
G. Discharge pressure, fully loaded, 2–3 compressors: . . . . . . . . . . . . . Circuit 1 __________ psig Circuit 2 __________ psig
H. Suction pressure, one compressor: . . . . . . . . . . . . . . . . . . . . . . Circuit 1 __________ psig Circuit 2 __________ psig
I. Suction pressure, fully loaded, 2–3 compressors: . . . . . . . . . . . . . . . Circuit 1 __________ psig Circuit 2 __________ psig
J. Liquid press, fully loaded, 2–3 compressors (at liquid line shutoff valve): . . . Circuit 1 __________ psig Circuit 2 __________ psig
K. Liquid temperature, fully loaded, 2–3 compressors: . .
. . . . . . . . . . . . Circuit 1 __________ psig Circuit 2 __________ psig
L. Suction line temperature: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ____________ °F ____________°F
M. Superheat: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ____________ °F ____________°F
N. Subcooling:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ____________ °F ____________°F
O. Is the liquid in the line sightglass clear and dry? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Yes No N/A
P. Does the hot gas bypass valve function properly?. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Yes No N/A
WarranTy reGIsTraTIon form
www.DaikinApplied.com 115 IM 1058-8 • MAVERICK II ROOFTOP SYSTEMS