User reference guide
R32 Split series – Domestic hot water tank
EKHWET90BAV3
EKHWET120BAV3

Other manuals for Daikin R32 Split Series

Questions and Answers

  • C
    christianspencerAug 18, 2025
    What to do if my Daikin R32 Split Air Conditioner has water leakage?
    • C
      Cindy WellsAug 18, 2025
      If you notice water leakage from your Daikin Air Conditioner, there are a couple of potential causes: * Incomplete thermal insulation of gas and liquid piping, including indoor portions of the drain hose extension. Ensure the thermal insulation of the piping and the drain hose is complete. * Improperly connected drainage. Make sure to secure the drainage.
  • M
    monica04Aug 20, 2025
    What to do if my Daikin R32 Split Air Conditioner unit does NOT function or shows burn damage?
    • R
      Ralph BowersAug 20, 2025
      If your Daikin Air Conditioner unit isn't functioning or shows signs of burn damage, the wiring may not have been performed according to specifications. Correct the wiring to resolve this issue.
  • A
    Angel FoxAug 23, 2025
    What to do if the LED is ON on my Daikin R32 Split?
    • D
      David DanielsAug 23, 2025
      If the LED is ON, turn the power OFF and then back ON. Check the LED within approximately 3 minutes. If the LED turns ON again, it indicates that the outdoor unit PCB is faulty.
  • C
    Cristian SimmonsAug 26, 2025
    Why is my Daikin R32 Split Air Conditioner not heating or cooling as expected?
    • S
      Seth HancockAug 26, 2025
      There are several reasons why your Daikin Air Conditioner might not be heating or cooling properly. It could be due to incorrect connection of the electrical wires, which requires you to connect them correctly. Another potential cause is gas leakage, so check for any signs of leakage. Also, ensure that the marks on the wiring and piping for each indoor unit match (room A, room B, room C, room D, room E).
  • S
    Sarah JohnsonAug 27, 2025
    What to do if my Daikin R32 Split Air Conditioner is leaking water?
    • R
      Robin RussoAug 28, 2025
      If your Daikin Air Conditioner is leaking water, it could be due to incomplete thermal insulation on the gas and liquid piping, as well as the indoor portions of the drain hose extension. Ensure the thermal insulation of the piping and the drain hose is complete. Another possible cause is improperly connected drainage, so make sure to secure the drainage.
  • T
    Terri Young DDSAug 30, 2025
    What to do if there's water leakage from my Daikin Air Conditioner?
    • S
      Sarah SanchezAug 30, 2025
      If you notice water leakage from your Daikin Air Conditioner, it could be due to incomplete thermal insulation of the gas and liquid piping, or the indoor portions of the drain hose extension. Ensure the thermal insulation of the piping and the drain hose is complete. Another cause might be improperly connected drainage, so secure the drainage.
  • J
    Jeremy PageSep 1, 2025
    How to fix Daikin R32 Split indoor units that fall, vibrate or make noise?
    • C
      Carla SheltonSep 1, 2025
      If the indoor units of your Daikin Air Conditioner are falling, vibrating, or making noise, ensure that you install them securely.
  • M
    Mrs. Erika MeyerSep 3, 2025
    Why is the LED OFF on my Daikin R32 Split?
    • D
      dlambSep 3, 2025
      The LED might be OFF due to supply voltage issues (related to power saving) or a power supply fault. To resolve this, turn the power OFF and then back ON. Check the LED within approximately 3 minutes. If the LED remains OFF, the outdoor unit PCB is likely faulty.
  • K
    ktoddSep 5, 2025
    How to fix electrical leakage in Daikin R32 Split Air Conditioner?
    • J
      Joshua AndersonSep 6, 2025
      If you have electrical leakage in your Daikin Air Conditioner, the unit might not be earthed correctly. Check and correct the connection of the earth wiring.
  • D
    Daniel LeeSep 8, 2025
    What to do if there is refrigerant leakage in the room from Daikin Water Heater?
    • B
      Brandi ThomasSep 8, 2025
      If you detect refrigerant leakage from your Daikin Water Heater: * Turn off any combustible heating devices. * Ventilate the room. * Contact the dealer where you purchased the unit. Do not use the unit until a service person confirms that the part from which the refrigerant leaked has been repaired.

Summary

About this document

Meaning of Warnings and Symbols

Explains the meaning of hazard symbols and warnings used in the manual.

User Safety Instructions

Safe Operation Guidelines

Details specific instructions for operating the appliance safely, including warnings about refrigerant.

Quick Guide

Operation

Domestic Hot Water Management

Details DHW control modes, schedules, preset values, and weather-dependent operation.

Energy Saving Tips

Maintenance and Service

Troubleshooting

Troubleshooting: Cold Tap Water

Addresses the symptom of insufficient hot water at the tap and its possible causes and solutions.

Troubleshooting: Heat Pump Failure

Covers issues related to heat pump failure and the role of the booster heater.

Installer Settings Tables

Daikin R32 Split Series Specifications

General IconGeneral
BrandDaikin
ModelR32 Split Series
CategoryAir Conditioner
LanguageEnglish

Related product manuals