EasyManua.ls Logo

Daikin RE35JV1 - Removal of Outdoor Fan; Fan Motor

Daikin RE35JV1
15 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Removal of Outdoor Fan / Fan Motor Si01-752
6 Removal Procedure
4. Removal of Outdoor Fan / Fan Motor
Procedure Warning Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step Procedure Points
1
Disconnect the 3
terminals of the fan
motor lead wire.
(2 from the fan motor
capacitor, 1 from the
magnetic contactor)
Nut size: M6
When reassembling, align
the mark of the outdoor
fan with the D-cut section of
the motor shaft.
The fan motor should be
restored so that the mark
z
will be at upper side.
2
Remove the nut and
remove the outdoor fan.
3
4
Open the 2 hooks and
release the fan motor
lead wire.
Remove the 2 screws
of the fan motor.
Fan motor
lead wire: black
Fan motor capacitorRedWhiteBlack
Fan motor
lead wire
Magnetic
contactor
A
View from A
(R12890)
10 mm
(R12236)
(R1861)
T Mark
(R12797)
D cut
z Mark
(R12798)
Hoo
k

Other manuals for Daikin RE35JV1

Related product manuals