Removal of Outdoor Fan / Fan Motor Si011194
8 Removal Procedure
4 Cut the 3 clamps and
release the fan motor
lead wire.
Some models have the 3
clamps at the different
positions.
Put the fan motor lead wire
through the back of the fan
motor when reassembling so
as not to be entangled with
the outdoor fan.
5 Remove the nut and
remove the outdoor fan.
Nut size: M6
Align the mark of the
outdoor fan with the D-cut
section of the motor shaft
when reassembling.
Step Procedure Points
Clamp
(R17195)
(R5404)
(R3249)
Lead wire Outdoor fan
D-cut
(R5405)
10 mm
(R17447)