EasyManua.ls Logo

Daikin RE60KV1 - Removal of Electrical Component ASSY

Daikin RE60KV1
18 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Si011194 Removal of Electrical Component ASSY
Removal Procedure 11
4. Removal of Electrical Component ASSY
Procedure Warning Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Step Procedure Points
1
Remove the terminal
cover.
2 Disconnect the
compressor lead wires.
Be careful so as not to burn
the compressor terminals or
the name plate.
S: yellow
C: blue
R: red
3 Remove the gasket.
Terminal cover
(R16171)
Terminal
cover
fixture
(R16227)
Yellow (S)
Blue (C)
Red (R)
(R16228)
(R12819)
S
R
C
Gasket
(R16229)