Si011194 Removal of Outdoor Fan / Fan Motor
Removal Procedure 7
2. Removal of Outdoor Fan / Fan Motor
Procedure Warning Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Step Procedure Points
1 Disconnect the relay
connector for the fan
motor.
2 Remove the 2 screws
of the fan motor fixing
plate.
3 Lift up and remove the
fan motor fixing plate.
Be careful so as not to
damage the top part of the
outdoor heat exchanger fins.
(R16233)
(R16234)
(R16849)