EasyManua.ls Logo

Daikin REYA16A7Y1B User Manual

Daikin REYA16A7Y1B
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Installation and operation manual
VRV 5 heat recovery
English
Installation and operation manual
VRV 5 heat recovery
REYA8A7Y1B
REYA10A7Y1B
REYA12A7Y1B
REYA14A7Y1B
REYA16A7Y1B
REYA18A7Y1B
REYA20A7Y1B
REMA5A7Y1B

Table of Contents

Questions and Answers:

Daikin REYA16A7Y1B Specifications

General IconGeneral
ModelREYA16A7Y1B
Energy Efficiency Class (Cooling)A++
RefrigerantR32
Operating Temperature Range (Heating)-15°C to 24°C
Operating Temperature Range (Cooling)10°C to 46°C

Summary

Specific Installer Safety Instructions

Installation Site Safety

Safety guidelines for installation site, covering service space, packaging, and accessibility.

Instructions for Equipment Using R32 Refrigerant

User Safety Instructions

Operation

Troubleshooting

Solving Problems Based on Error Codes

Provides guidance on resolving system issues by interpreting and acting on error codes.

Error Codes Overview

Special Requirements for R32 Units

About the Charge Limit

To Determine the Charge Limit

Unit Installation

Installation Site Requirements of the Outdoor Unit

Opening the Unit

To Open the Electrical Component Box of the Outdoor Unit

Mounting the Outdoor Unit

Piping Installation

Refrigerant Piping Requirements

Refrigerant Piping Material

To Select the Piping Size

To Select Refrigerant Branch Kits

Connecting the Refrigerant Piping

Checking the Refrigerant Piping

About Checking the Refrigerant Piping

Explains when and how to perform refrigerant piping checks, including leak tests and vacuum drying.

Checking Refrigerant Piping: General Guidelines

Provides general guidelines for performing refrigerant piping checks, including equipment setup.

Checking Refrigerant Piping: Setup

Details the setup required for performing refrigerant piping checks, including necessary equipment.

To Perform a Leak Test

To Perform Vacuum Drying

Charging Refrigerant

Precautions When Charging Refrigerant

Outlines essential precautions to take before and during refrigerant charging operations.

About Charging Refrigerant

Explains the process of charging refrigerant after vacuum drying is completed.

To Determine the Additional Refrigerant Amount

To Charge Refrigerant: Flow Chart

To Charge Refrigerant

Error Codes When Charging Refrigerant

Checks After Charging Refrigerant

To Check for Refrigerant Leaks After Charging

Electrical Installation

Safety Device Requirements

Specifies the required safety devices, such as fuses and circuit breakers, for power supply protection.

To Route and Fix the Transmission Wiring

To Connect the Transmission Wiring

To Finish the Transmission Wiring

To Connect the Power Supply

To Connect the External Outputs

Configuration

Making Field Settings

Guides the user through the process of making essential field settings for system configuration.

Field Setting Components

To Access the Field Setting Components

To Access Mode 1 or 2

To Use Mode 1

To Use Mode 2

Mode 1: Monitoring Settings

Mode 2: Field Settings

Commissioning

Checklist During Commissioning

About the BS Unit Test Run

About the Test Run

To Perform a Test Run

Error Codes: Overview

Refrigerant Leak Detection System

Wiring Diagram: Outdoor Unit

Related product manuals