Installation and operation manual
VRV 5 heat recovery
English
Installation and operation manual
VRV 5 heat recovery
REYA8A7Y1B
REYA10A7Y1B
REYA12A7Y1B
REYA14A7Y1B
REYA16A7Y1B
REYA18A7Y1B
REYA20A7Y1B
REMA5A7Y1B

Table of Contents

Questions and Answers

  • K
    Krista PittsAug 9, 2025
    Why is my Daikin REYA10A7Y1B not cooling or heating enough?
    • R
      Robert JacksonAug 10, 2025
      There could be several reasons why your Daikin Heating System isn't providing sufficient cooling or heating: * Check for any obstructions blocking the air inlet or outlet of either the outdoor or indoor unit. Remove any obstacles to ensure free airflow. * Make sure the air filter is clean. * Verify that the temperature setting is correct. * Adjust the fan speed setting on the user interface. * Ensure all doors and windows are closed to prevent drafts. * Consider if there are too many people in the room or excessive heat sources. * Block direct sunlight using curtains or blinds. * Confirm the air flow angle is properly adjusted.
  • C
    Carolyn PittsAug 20, 2025
    What to do if my Daikin REYA10A7Y1B Heating System doesn't operate at all?
    • B
      Brandon KochAug 20, 2025
      If your Daikin Heating System isn't operating, there are a couple of things you can check: 1. First, verify that there is no power failure and wait for the power to be restored. The system should automatically restart after power is restored. 2. Next, check if a fuse has blown or a breaker has tripped. If necessary, replace the fuse or reset the breaker.
  • K
    kathyowensAug 29, 2025
    What to do if my Daikin Heating System goes into fan only operation and then stops?
    • M
      Michael WallerAug 29, 2025
      If your Daikin Heating System enters fan-only mode and then stops when attempting to heat or cool, check the following: * Ensure that neither the air inlet nor the outlet of the outdoor or indoor unit is blocked by any obstacles. Clear any obstructions to allow for unrestricted airflow. * Verify that the user interface display shows on the home screen. Refer to the installation and operation manual delivered with the indoor unit for instructions.

Summary

Specific Installer Safety Instructions

Instructions for Equipment Using R32 Refrigerant

Highlights safety measures and warnings specific to R32 refrigerant handling.

Electrical Installation

Covers essential electrical connection procedures and safety compliance.

Commissioning

Details the process for system setup and operational verification.

Troubleshooting

Guidance for installers to identify and resolve common operational problems.

User Safety Instructions

Operation

Maintenance and Service

Troubleshooting

Error Codes: Overview

A comprehensive list and explanation of system error codes.

Solving Problems Based on Error Codes

Procedures for resolving system issues by referencing error codes.

Refrigerant Leak Detection System

Explains the functionality and operation of the refrigerant leak detection system.

Special Requirements for R32 Units

Installation Space Requirements

Defines the necessary space, clearances, and room area for R32 unit installations.

System Layout Requirements

Covers R32 system configuration rules and essential safety measures.

Unit Installation

Preparing the Installation Site

Ensures the installation location meets all safety and operational prerequisites.

Piping Installation

Preparing Refrigerant Piping

Guidelines for selecting materials, sizes, and temper grades for piping.

Connecting the Refrigerant Piping

Detailed steps for connecting refrigerant pipes to various unit components.

Checking the Refrigerant Piping

Procedures for leak testing and vacuum drying of the installed piping.

Charging Refrigerant

Precautions When Charging Refrigerant

Critical safety measures and warnings before initiating refrigerant charging.

To Determine the Additional Refrigerant Amount

Methodology for calculating the precise amount of additional refrigerant needed.

To Check for Refrigerant Leaks After Charging

Procedure to verify system integrity and detect leaks post-charging.

Electrical Installation

Configuration

Making Field Settings

Guides on configuring system parameters via the PCB and 7-segment display.

Commissioning

Precautions When Commissioning

Important safety and preparatory steps before commencing commissioning.

Hand-over to the User

Daikin REYA10A7Y1B Specifications

General IconGeneral
ModelREYA10A7Y1B
ManufacturerDaikin
Energy Efficiency Class (Heating)A++
RefrigerantR-32
Operating Temperature Range (Heating)-25°C to 35°C
CategoryAir Conditioner
TypeAir-to-Water Heat Pump
Heating Capacity10.0 kW
Sound Pressure Level Heating45 dB(A) at 10m
Power Supply230V / 50Hz / 1~