EasyManua.ls Logo

Daikin REYQ96TTJU User Manual

Daikin REYQ96TTJU
46 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
English
Français
Español
INSTALLATION MANUAL
MODEL
REYQ72TTJU
REYQ96TTJU
REYQ120TTJU
REYQ144TTJU
REYQ168TTJU
REYQ192TTJU
REYQ216TTJU
REYQ240TTJU
REYQ264TTJU
REYQ288TTJU
REYQ312TTJU
REYQ336TTJU
REYQ360TTJU
REYQ384TTJU
REYQ408TTJU
REYQ432TTJU
REYQ456TTJU
REYQ72TYDN
REYQ96TYDN
REYQ120TYDN
REYQ144TYDN
REYQ168TYDN
REYQ192TYDN
REYQ216TYDN
REYQ240TYDN
REYQ264TYDN
REYQ288TYDN
REYQ312TYDN
REYQ336TYDN
REYQ360TYDN
REYQ384TYDN
REYQ408TYDN
REYQ432TYDN
REYQ456TYDN
System Air Conditioner
3P362438-3H
00_CV_3P362438-3H.indd 1 1/5/2015 9:24:22 AM

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Daikin REYQ96TTJU and is the answer not in the manual?

Daikin REYQ96TTJU Specifications

General IconGeneral
ModelREYQ96TTJU
SeriesVRV IV
CategoryAir Conditioner
TypeHeat Pump
Cooling Capacity96, 000 BTU/h
RefrigerantR-410A
Power Supply208-230V/3Ph/60Hz

Summary

Safety considerations

Codes and Regulations

4. Selecting an installation location

4.1. General precautions on installation

Outlines general site selection requirements for proper unit installation, stability, and air circulation.

7. Refrigerant pipe size and allowable pipe length

7.3. Selection of piping size

Guides on selecting proper piping sizes using tables and diagrams based on outdoor unit capacity and connection type.

7.5. System piping (length) limitations

Outlines maximum allowable lengths, height differences, and branch limitations for refrigerant piping systems.

8. Precautions on refrigerant piping

8.1. Caution for brazing

Provides precautions for brazing refrigerant piping to prevent contamination, damage, and ensure system integrity.

8.2. Connecting the refrigerant piping

Details the procedures for connecting refrigerant piping, including front, side connections, and removing pinched pipes.

9. Field wiring

9.1. Power circuit, safety device and cable requirements

Details power circuit requirements, safety devices, and cable specifications, including wiring regulations and circuit protection.

9.4. Transmission wiring connection procedure

Details the procedure for connecting transmission wiring between various unit types, including limitations.

10. Air tight test and vacuum drying

11. Pipe insulation

12. Checking of device and installation conditions

14. Charging refrigerant

14.1. Precautions

Lists essential precautions before and during refrigerant charging, including safety measures and R410A handling.

14.2. Calculating the additional refrigerant charge

Explains how to calculate the required additional refrigerant charge using formulas based on piping and capacity.

14.3. Method for adding refrigerant

Details the procedures for adding refrigerant using automatic or manual charging methods, including flow charts.

15. Start-up and configuration

15.2. Monitoring function and field settings

Explains how to monitor unit status and configure field settings using modes 1 and 2.

15.3. Energy saving and optimum operation

Explains energy-saving features and optimum operation settings for balancing comfort and consumption.

15.4. Test operation

Details the procedure for performing a system test operation to verify functionality and identify issues.

15.5. Malfunction code list

Provides a comprehensive list of malfunction codes, their subcodes, contents, and recommended solutions for troubleshooting.