INSTALLATION
MANUAL
R410A Split Series
Models
RXS20CVMB RKS20CVMB
RXS25CVMB RKS25CVMB
RXS35CVMB RKS35CVMB
ARXS20CVMB ARKS20CVMB
ARXS25CVMB ARKS25CVMB
ARXS35CVMB ARKS35CVMB
RXS20C2VMB RKS20C2VMB
RXS25C2VMB RKS25C2VMB
RXS35C2VMB RKS35C2VMB
ARXS20C2VMB ARKS20C2VMB
ARXS25C2VMB ARKS25C2VMB
ARXS35C2VMB ARKS35C2VMB
RXG25CVMB RXG25E2V1B
RXG35CVMB RXG35E2V1B
ARXG25CVMB ARXG25E2V1B
ARXG35CVMB ARXG35E2V1B
Deutsch
Français
Nederlands
Español
Italiano
ΕλληνικÜ
Portugues
Рóссêий
English
Türkçe
Installation manual
R410A Split series
Montaj kýlavuzlarý
R410A Split serisi
Installationsanleitung
Split-Baureihe R410A
Manuel d’installation
Série split R410A
Montagehandleiding
R410A Split-systeem
Manual de instalación
Serie Split R410A
Manuale d’installazione
Serie Multiambienti R410A
Εγχειρßδιο εγκατÜστασηò
διαιροýìενηò σειρÜò R410A
Manual de Instalação
Série split R410A
Рóêоводство по монтажó
Серия R410A с раздельной óстановêой
00_CV_3P119321-7W.fm Page 1 Thursday, March 8, 2007 5:43 PM

Other manuals for Daikin RKS35CVMB

Questions and Answers

  • E
    ecolemanAug 14, 2025
    Why is my Daikin RKS35CVMB Air Conditioner outdoor unit leaking water?
    • Q
      qortizAug 14, 2025
      In HEAT mode, the frost on the outdoor unit melts into water or steam during defrost operation. In COOL or DRY mode, moisture in the air condenses into water on the cool surface of the outdoor unit piping and drips.
  • J
    Jennifer McgeeAug 17, 2025
    Why does my Daikin Air Conditioner smell?
    • W
      William PerezAug 17, 2025
      The Daikin Air Conditioner may emit odors because smells from the room, furniture, or cigarettes have been absorbed into the unit and are being discharged with the airflow. It is recommended to have the indoor unit cleaned by a technician. Consult the service shop where you bought the air conditioner.
  • H
    Henry ConnerAug 21, 2025
    What to do if my Daikin RKS35CVMB heating stops suddenly?
    • D
      David FergusonAug 21, 2025
      The system is likely removing frost from the outdoor unit. You should wait for about 3 to 8 minutes.
  • M
    miguellindseyAug 25, 2025
    Why doesn't hot air come out immediately from my Daikin RKS35CVMB when heating?
    • G
      Gary ShieldsAug 26, 2025
      You should wait for 1 to 4 minutes. The system is designed to start discharging air only after it has reached a certain temperature.
  • S
    Suzanne MendezAug 28, 2025
    Why my Daikin RKS35CVMB does not start immediately?
    • J
      Jennifer GuzmanAug 29, 2025
      If the ON/OFF button was pressed soon after operation was stopped, or if the mode was reselected, you should wait for about 3 minutes.
  • B
    Bonnie RichardsonSep 1, 2025
    What to do if my Daikin RKS35CVMB Air Conditioner operation stopped suddenly?
    • W
      William DiazSep 1, 2025
      For system protection, the air conditioner may stop operating due to a sudden large voltage fluctuation. It will automatically resume operation in about 3 minutes.
  • J
    Joyce SaundersSep 4, 2025
    Why is the Daikin Air Conditioner outdoor fan running when it's off?
    • K
      Krista PearsonSep 5, 2025
      After operation is stopped, the outdoor fan may continue rotating for another 60 seconds for system protection. Also, when the outdoor temperature is very high, the outdoor fan might start rotating for system protection even when the air conditioner is not in operation.
  • P
    Philip AdkinsSep 9, 2025
    Why does mist come out of my Daikin RKS35CVMB Air Conditioner?
    • N
      Natalie MillerSep 9, 2025
      This happens when the air in the room is cooled into mist by the cold air flow during cooling operation.

Summary

Safety Precautions

General WARNINGs

Critical safety instructions detailing severe consequences like death or injury if not followed.

General CAUTIONs

Safety instructions where failure to follow may lead to grave consequences.

Precautions for Selecting the Location

Outdoor Unit Installation

Flaring the Pipe End

Detailed steps for preparing pipe ends for connections, including flaring techniques.

Refilling The Refrigerant

Guidance on refilling refrigerant, including precautions for R410A.

Purging Air and Checking Gas Leakage

Pump Down Operation

Wiring

Test Run and Final Check

Daikin RKS35CVMB Specifications