Installer reference guide
R32 split series
RXF50B2V1B
RXF60B2V1B
RXF71A2V1B
ARXF50A2V1B
ARXF60A2V1B
ARXF71A2V1B
RXP50M2V1B
RXP60M2V1B
RXP71M2V1B
ARXM50R2V1B
ARXM60R2V1B
ARXM71R2V1B
RXM42R2V1B
RXM50R2V1B
RXM60R2V1B
RXM71R2V1B
RXJ50N2V1B
RXA42B2V1B
RXA50B2V1B

Table of Contents

Other manuals for Daikin RXF71A2V1B

Questions and Answers

  • M
    miguel59Jul 25, 2025
    What to do if my Daikin RXF71A2V1B Air Conditioner has water leakage?
    • P
      Paula SotoJul 25, 2025
      If you notice water leakage from your Daikin Air Conditioner, there are a couple of potential causes: * Incomplete thermal insulation of gas and liquid piping, including indoor portions of the drain hose extension. Ensure the thermal insulation of the piping and the drain hose is complete. * Improperly connected drainage. Make sure to secure the drainage.
  • D
    Dustin OrtizJul 30, 2025
    What to do if my Daikin RXF71A2V1B Air Conditioner unit does NOT function or shows burn damage?
    • C
      Crystal ReevesJul 30, 2025
      If your Daikin Air Conditioner unit isn't functioning or shows signs of burn damage, the wiring may not have been performed according to specifications. Correct the wiring to resolve this issue.
  • J
    Jeffrey GallegosAug 3, 2025
    Why is my Daikin RXF71A2V1B Air Conditioner not heating or cooling as expected?
    • K
      Katherine JonesAug 3, 2025
      Your Daikin Air Conditioner might not be heating or cooling as expected due to a few reasons. It could be due to incorrect connection of the electrical wires, in which case you should connect the electrical wires correctly. Another potential cause is gas leakage, so check for any gas leakage.
  • H
    Heather JarvisAug 7, 2025
    What to do if there's water leakage from my Daikin RXF71A2V1B?
    • L
      lthompsonAug 7, 2025
      If you notice water leakage from your Daikin Air Conditioner, it could be due to incomplete thermal insulation of the gas and liquid piping, or the indoor portions of the drain hose extension. Ensure the thermal insulation of the piping and the drain hose is complete. Another cause might be improperly connected drainage, so secure the drainage.
  • J
    Joshua BenitezAug 11, 2025
    How to fix Daikin RXF71A2V1B indoor units that fall, vibrate or make noise?
    • J
      joshuaalvarezAug 11, 2025
      If the indoor units of your Daikin Air Conditioner are falling, vibrating, or making noise, ensure that you install them securely.
  • T
    Tony JacksonAug 15, 2025
    What to do if my Daikin RXF71A2V1B Air Conditioner has electrical leakage?
    • L
      Lauren TravisAug 16, 2025
      If you're experiencing electrical leakage with your Daikin Air Conditioner, it's likely that the unit isn't earthed correctly. Check and correct the connection of the earth wiring.
  • A
    Austin CruzAug 20, 2025
    What to do if I suspect electrical leakage from my Daikin RXF71A2V1B?
    • C
      coxcynthiaAug 20, 2025
      If you suspect electrical leakage from your Daikin Air Conditioner, it's likely that the unit is not earthed correctly. Check and correct the connection of the earth wiring.

Summary

General Safety Precautions

Refrigerant Handling Safety

Safety precautions related to handling R32 refrigerant and potential risks.

Unit Installation

Piping Installation

Connecting Refrigerant Piping

Procedures and safety precautions for connecting refrigerant pipes.

Checking Refrigerant Piping

Procedures for checking refrigerant piping for leaks and performing vacuum drying.

Electrical Installation

Electrical Wiring Precautions

Critical safety warnings for electrical wiring installation.

Charging Refrigerant

Charging Additional Refrigerant

Step-by-step guide for adding refrigerant to the system.

Troubleshooting

Solving Problems by Symptom

Guides to diagnose and resolve issues based on observed symptoms.

Technical Data

Daikin RXF71A2V1B Specifications

General IconGeneral
CategoryAir Conditioner
ModelRXF71A2V1B
Cooling Capacity7.1 kW
Heating Capacity8.0 kW
RefrigerantR32
Power Supply220-240 V, 50 Hz
Outdoor Unit Noise Level49 dB