REMOVAL
PROCEDURE
SERVICE MANUAL
4.6/5.0/6.0/7.1 kW Class
Outdoor Unit
Inverter
Pair Type
Si001654EA
Question and Answer IconNeed help?

Do you have a question about the Daikin RXF71QVMA and is the answer not in the manual?

Daikin RXF71QVMA Specifications

General IconGeneral
CategoryAir Conditioner
ModelRXF71QVMA
Cooling Capacity7.1 kW
Heating Capacity8.0 kW
RefrigerantR32
Power Supply220-240V, 50Hz

Summary

Outer Panels

Outdoor Fan and Fan Motor Removal

Electrical Box Removal

Thermistor Assembly and PCB Removal

Thermistor Assembly Removal

Procedure for removing the thermistor assembly from the unit's electrical components.

Main PCB Removal

Procedure for removing the main printed circuit board (PCB) from the unit.

Partition Plate and Sound Blankets

Partition Plate Removal

Procedure for removing the partition plate from the unit's interior.

Sound Blankets Removal

Procedure for removing the top and outer sound blankets from the unit.

Expansion Valve and Four Way Valve

Compressor Removal