Do you have a question about the Daikin RXN09NMVJU and is the answer not in the manual?
Detach connectors, remove ground wire, and disconnect wiring from the terminal board.
Remove screws, spacers, and hooks to detach the printed circuit board (PCB).
Remove stop valve cover by sliding downwards and remove protection plate using screws.
Remove conduit mounting plate cover and right side panel using screws.
Pull out thermistor holder, cut clamp, and remove outdoor heat exchanger thermistor.
Remove discharge pipe temperature thermistor and the main thermistor ASSY.
Remove the reactor by unscrewing it and sliding it upwards.
Pull out the electronic expansion valve coil from its mounting.
Remove the partition plate by unscrewing it and lifting it up.
Remove the screw securing the four way valve coil and detach it.
Remove terminal cover, disconnect wires, and heat/disconnect brazed parts for valve removal.
Remove the terminal cover from the compressor unit.
Remove protection bushing, disconnect wires, heat/disconnect pipes, and lift out the compressor.
| Power Supply | 1 Phase, 60 Hz |
|---|---|
| Noise Level (Outdoor Unit) | 46 dB(A) |
| Type | Split System |
| Cooling Capacity | 9000 BTU/h |
| Cooling Capacity (BTU/h) | 9000 BTU/h |
| Sound Level (Indoor) | 19 dB(A) |
| Voltage | 220-240 V |
| Energy Efficiency Ratio (Heating) | 4.0 |
| Refrigerant | R-32 |