REMOVAL
PROCEDURE
SERVICE MANUAL
Outdoor Unit
Inverter
Pair Type
9000/12000 Btu/h Class
Si001554EA

Other manuals for Daikin RXN09NMVJU

Question and Answer IconNeed help?

Do you have a question about the Daikin RXN09NMVJU and is the answer not in the manual?

Summary

Outer Panels Removal

Outdoor Fan and Fan Motor Removal

Electrical Box and PCB Removal

Remove the Electrical Box

Detach connectors, remove ground wire, and disconnect wiring from the terminal board.

Remove the PCB

Remove screws, spacers, and hooks to detach the printed circuit board (PCB).

Thermistor ASSY Removal

Stop Valve Cover and Protection Plate Removal

Remove stop valve cover by sliding downwards and remove protection plate using screws.

Conduit Plate and Side Panel Removal

Remove conduit mounting plate cover and right side panel using screws.

Thermistor Holder and Heat Exchanger Thermistor Removal

Pull out thermistor holder, cut clamp, and remove outdoor heat exchanger thermistor.

Discharge Pipe Thermistor and Thermistor ASSY Removal

Remove discharge pipe temperature thermistor and the main thermistor ASSY.

Sound Blankets Removal

Reactor, EEV Coil, and Partition Plate Removal

Reactor Removal

Remove the reactor by unscrewing it and sliding it upwards.

Electronic Expansion Valve Coil Removal

Pull out the electronic expansion valve coil from its mounting.

Partition Plate Removal

Remove the partition plate by unscrewing it and lifting it up.

Four Way Valve Removal

Four Way Valve Coil Removal

Remove the screw securing the four way valve coil and detach it.

Four Way Valve Component Disconnection and Removal

Remove terminal cover, disconnect wires, and heat/disconnect brazed parts for valve removal.

Compressor Removal

Compressor Terminal Cover Removal

Remove the terminal cover from the compressor unit.

Compressor Components and Compressor Removal

Remove protection bushing, disconnect wires, heat/disconnect pipes, and lift out the compressor.

Daikin RXN09NMVJU Specifications

General IconGeneral
Power Supply1 Phase, 60 Hz
Noise Level (Outdoor Unit)46 dB(A)
TypeSplit System
Cooling Capacity9000 BTU/h
Cooling Capacity (BTU/h)9000 BTU/h
Sound Level (Indoor)19 dB(A)
Voltage220-240 V
Energy Efficiency Ratio (Heating)4.0
RefrigerantR-32