1 English
Safety Precautions
•TheprecautionsdescribedhereinareclassiedasWARNINGandCAUTION.Theybothcontainimportantinforma-
tionregardingsafety.Besuretoobserveallprecautionswithoutfail.
•MeaningofWARNINGandCAUTIONnotices
WARNING ........
Failure to follow these instructions properly may result in personal injury or loss of life.
CAUTION .........
Failure to observe these instructions properly may result in property damage or personal injury, which
may be serious depending on the circumstances.
•Thesafetymarksshowninthismanualhavethefollowingmeanings:
Besuretofollowtheinstructions. Besuretoestablishanearthconnection. Neverattempt.
•Aftercompletinginstallation,conductatrialoperationtocheckforfaultsandexplaintothecustomerhowtooperate
theairconditionerandtakecareofitwiththeaidoftheoperationmanual.
WARNING
•Askyourdealerorqualiedpersonneltocarryoutinstallationwork.
Donotattempttoinstalltheairconditioneryourself.Improperinstallationmayresultinwaterleakage,electricshocksorre.
•Installtheairconditionerinaccordancewiththeinstructionsinthisinstallationmanual.
Improperinstallationmayresultinwaterleakage,electricshocksorre.
•Besuretouseonlythespeciedaccessoriesandpartsforinstallationwork.
Failuretousethespeciedpartsmayresultintheunitfalling,waterleakage,electricshocksorre.
•Installtheairconditioneronafoundationstrongenoughtowithstandtheweightoftheunit.
Afoundationofinsufcientstrengthmayresultintheequipmentfallingandcausinginjury.
•Electricalworkmustbeperformedinaccordancewithrelevantlocalandnationalregulationsandwithinstructions
inthisinstallationmanual.Besuretouseadedicatedpowersupplycircuitonly.
Insufciencyofpowercircuitcapacityandimproperworkmanshipmayresultinelectricshocksorre.
•Useacableofsuitablelength.
Donotusetappedwiresoranextensionlead,asthismaycauseoverheating,electricshocksorre.
•
Makesurethatallwiringissecured,thespeciedwiresareused,andthatthereisnostrainontheterminalconnectionsorwires.
Improperconnectionsorsecuringofwiresmayresultinabnormalheatbuild-uporre.
•Whenwiringthepowersupplyandconnectingthewiringbetweentheindoorandoutdoorunits,positionthewires
sothatthecontrolboxlidcanbesecurelyfastened.
Improperpositioningofthecontrolboxlidmayresultinelectricshocks,reoroverheatingterminals.
•Ifrefrigerantgasleaksduringinstallation,ventilatetheareaimmediately.
Toxicgasmaybeproducediftherefrigerantcomesintocontactwithre.
•Aftercompletinginstallation,checkforrefrigerantgasleakage.
Toxicgasmaybeproducediftherefrigerantgasleaksintotheroomandcomesintocontactwithasourceofre,suchasafanheater,stoveorcooker.
•Wheninstallingorrelocatingtheairconditioner,besuretobleedtherefrigerantcircuittoensureitisfreeofair,
anduseonlythespeciedrefrigerant(R410A).
Thepresenceofairorotherforeignmatterintherefrigerantcircuitcausesabnormalpressurerise,whichmayresultinequipmentdamageandeveninjury.
•Duringinstallation,attachtherefrigerantpipingsecurelybeforerunningthecompressor.
Iftherefrigerantpipesarenotattachedandthestopvalveisopenwhenthecompressorisrun,airwillbesuckedin,causingabnormal
pressureintherefrigerationcycle,whichmayresultinequipmentdamageandeveninjury.
•Duringpump-down,stopthecompressorbeforeremovingtherefrigerantpiping.
Ifthecompressorisstillrunningandthestopvalveisopenduringpump-down,airwillbesuckedinwhentherefrigerantpipingisremoved,
causingabnormalpressureintherefrigerationcycle,whichmayresultinequipmentdamageandeveninjury.
•Besuretoearththeairconditioner.
Donotearththeunittoautilitypipe,lightningconductorortelephoneearthlead.Imperfectearthingmayresultinelectricshocks.
•Besuretoinstallanearthleakagebreaker.
Failuretoinstallanearthleakagebreakermayresultinelectricshocksorre.
CAUTION
•Donotinstalltheairconditioneratanyplacewherethereisadangerofammablegasleakage.
Intheeventofagasleakage,build-upofgasneartheairconditionermaycausearetobreakout.
•Whilefollowingtheinstructionsinthisinstallationmanual,installdrainpipingtoensureproperdrainageand
insulatepipingtopreventcondensation.
Improperdrainpipingmayresultinindoorwaterleakageandpropertydamage.
•Tightenthearenutaccordingtothespeciedmethodsuchaswithatorquewrench.
Ifthearenutistootight,itmaycrackafterprolongeduse,causingrefrigerantleakage.
•
Makesuretoprovideforadequatemeasuresinordertopreventthattheoutdoorunitbeusedasashelterbysmallanimals.
Smallanimalsmakingcontactwithelectricalpartscancausemalfunctions,smokeorre.Pleaseinstructthecustomertokeeptheareaaroundtheunitclean.
•Thetemperatureofrefrigerantcircuitwillbehigh,pleasekeeptheinter-unitwireawayfromcopperpipesthatare
notthermallyinsulated.
01_EN_3P297037-2D.indd 1 11/1/2012 11:04:40 AM

Other manuals for Daikin RXS35J2V1B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin RXS35J2V1B and is the answer not in the manual?

Daikin RXS35J2V1B Specifications

General IconGeneral
BrandDaikin
ModelRXS35J2V1B
CategoryAir Conditioner
LanguageEnglish

Related product manuals